The value shown on the display must be ‘
without pump
’; if necessary, change the value by pressing the UP/DOWN
buttons.
Confi rm by pressing
OK
.
Continue pressing the
MENU
button repeatedly until you can see on the display:
Heating Type
xxxxxxx
The value shown on the display must be ‘
Pressure Switch
’; if necessary, change the value by pressing the UP/
DOWN buttons.
Confi rm by pressing
OK
.
Press the
MENU
button various times until the display shows the ‘OFF’ message.
Press the ‘I/O’ or ‘Non-Stop’ button, based on the machine model, in order to turn on the machine.
ATTENTION:
It is absolutely necessary that the values of the parameters ‘MIXED TEA’ and ‘HEATING TYPE’
are ‘
without pump
’ and ‘
Pressure Switch
’, respectively, for machines with a display and boiler temperature
controlled by pressure switch.
D. LACK OF IMPULSES FROM THE FLOW METER
When the fl ow meter is not dosing correctly or the necessary impulses do not arrive for longer than 5 continuous
seconds, the used dose selection LED will fl ash and the display will indicate the fl ow meter and the group.
Alarm
Flow meter GR x
To eliminate this alarm, check the fl ow meters; this alarm signal is produced due to a bypass of the signal from the
meter cover, or due to a poor connection, or lastly due to and internal problem with the control unit.
It can also be caused by an unusually long feed time due to the water not fl owing at an adequate speed during
dispensing.
E. CHANGE/REPLACE water fi lter
When the number of litres of water set in the TECHNICAL MENU is exceeded, the display will show:
ChangeWaterFilt.
xxxxxxx
With the number of litres of water previously selected to set off the alarm.
To eliminate this alarm, press the GROUP 1 ‘2 coff ees’ and ‘2 espressos’ buttons at the same time on (on the left).
The display will then show:
Filter Reset
Pressure Switch
Xxxxxxx On/Off
PID