For the union of the collectors it is not necessary to use any welding process,
glues or other materials, the fitting is done through male / female threaded
connections, it is enough to fit one collector to the other or a collector to the
system piping.
The collectors must be installed on a flat surface, favoring the proper union
between them and avoiding leaks.
During transportation and handling, excess weight on the collectors must
be avoided in order to avoid possible damage to the equipment.
7.2.
Tests and Verifications
Before running water through the system:
1. Check that all connectors are locked and tight.
2. Check that all supports are attached to the roof and aligned.
3. Check that all piping is supported or secured.
Test the system:
1. With water in the filter / pool tubing, open the collector supply and return
valves.
2. Activate the controller, the solar heating system pump, operating in “ma-
nual” mode.
3. Check for any leaks by checking all connections, including between the
collectors, and that the piping has remained secure and firm.
14
8.
Maintenance
This section will allow you to identify some of the most common causes of
operating problems.
8.1.
Solutions Framework