Inclined collectors produce more energy during periods of mild temperatures,
in addition to promoting the flow of water inside.
The installation must be done avoiding shaded areas. Observe if the installa-
tion site of the collectors supports the dimensioned quantity and the weight
of these collectors filled with water. Leave enough space for the maintenance
of the collectors.
4.1.
Inclination angle
Ideally, the angle of inclination varies from the latitude of the place to latitude
+ 15 degrees, in most cases, in Brazil, 17 degrees is enough.
The direction of the collectors should be towards the geographical north.
In case it is not possible, there will be a need to make a correction in the cal-
culation of their quantity.
Up to 15⁰ deviation to the east or west there is no need for correction.
Otherwise, use the guidelines, as shown in the table below:
07
For correct dimensioning of the required number of plates, the recommended
temperature must be taken into account for each type of pool use, according
to the temperatures recommended in the table below.
The following table indicates the recommended multiplication factor for
calculating the collector area required for the pool to be heated to the same
temperature in hot and cold climates.
For vinyl pools, check with the vinyl manufacturer for the ideal temperature.
Dimensioning Plates Quantity
Example: For a pool 6.00 m X 3.00 m = 18 m² of water depth. In hot climates, 6 VIBEA
3x1 plates or 9 VIBEA plates are installed.