2-5
BOILER SYSTEMS AND OPERATION
SFC COMBI BOILERS SFC-99, SFC-125
2.4 TANKLESS DOMESTIC HOT WATER
MODES
2.4.1 Tankless Domestic Hot Water - Standard and
ECO Comfort Modes
Standard Mode (OFF):
The unit will respond to a call for domestic hot water as
a priority over the space heating demand. When the domestic hot water demand
is satisfied the unit will return to the space heating load if the load is still calling.
The water heater’s heat exchanger will not maintain its domestic hot water
temperature between demands for hot water.
Comfort Mode (ON):
The water heater’s heat exchanger is maintained at the
DHW temperature.
ECO Comfort Mode (ECO):
This mode operates like the Comfort Mode but has
the added advantage of learning when the domestic hot water is used. During the
low use periods, the heat exchanger is allowed to cool.
To switch between the 3 modes:
1. Touch the area above the dot.
2. Touch the Faucet button twice.
.
3. Select the Plus or Minus buttons.
4.
To:
•
Save the changes, touch the Return button.
•
Exit without saving the changes, touch the area above the dot.
.
Содержание SFC-99
Страница 54: ...INSTALLATION AND OPERATION INSTRUCTIONS 2 8 SFC COMBI BOILERS SFC 99 SFC 125 PAGE INTENTIONALLY LEFT EMPTY...
Страница 75: ...6 1 DIAGRAMS SFC COMBI BOILERS SFC 99 SFC 125 6 0 DIAGRAMS 6 1 PARTS DIAGRAMS 6 2 WIRING DIAGRAMS...
Страница 81: ...SERVICE RECORD DATE LICENSED CONTRACTOR DESCRIPTION OF WORK DONE...