You must be a qualified technician to perform a fuel conversion. 

Model Number

Orifice Size

SFC-199

535

Table 2 

 - Propane Orifice Chart

To perform a fuel conversion:

 1.  Turn off the gas supply at the gas shut-off valve.

 2.  Disconnect the electrical power.

 3.  Disconnect the nut at the gas valve outlet (top of the gas valve), and remove the O-ring and orifice.

 4.  Insert the correct orifice into the O-ring, and re-install into the nut at the gas valve outlet (top of the gas valve), 

and then tighten the nut.

 5.  Restore the gas supply by opening the gas control valve.

 6.  Test for leaks by using an approved leak detection solution on all joints.

 7.  Power on the  appliance.

Now, carefully follow the procedures on Combustion Testing and Adjustment.

Содержание SFC-199

Страница 1: ...codes and requirements of the authority having jurisdiction If the information in these instructions is not followed exactly a fire an explosion or production of carbon monoxide may result causing pro...

Страница 2: ...rting the appliance to propane a combustion CO2 reading must be taken by a qualified technician using properly functioning and calibrated combustion analyzing equipment and the results compared to the...

Страница 3: ...connect the electrical power 3 Disconnect the nut at the gas valve outlet top of the gas valve and remove the O ring and orifice 4 Insert the correct orifice into the O ring and re install into the nu...

Страница 4: ...ion the appliance locks out and will need to be manually reset by pressing the Return Arrow button To perform a combustion test and adjustment 1 Turn off the appliance s gas shut off valve 2 With a sm...

Страница 5: ...e Adjustment cap to reveal a Torx head screw b Make tiny adjustments typically less than 1 8th of a turn at a time Turn the screw clockwise to increase CO2 and counter clockwise to reduce CO2 If the t...

Страница 6: ...ce will not shut off 4 With a Stop Watch record the number of seconds for the smallest dial to make 1 full revolution 5 CFH 3600 x Dial Size Seconds 6 CFH x 1000 check local Btu content Input Btu s No...

Страница 7: ...SFC 199 Fuel Conversion to Propane NG to LP Kit P 844 7 Where to Place Conversion Labels on the appliance...

Отзывы: