background image

Page 6

EXAMPLE

The medium and maximum capacities of a single unit from Table 4 are 36000 and 49000
respectively. The calculated capacity falls closer to the maximum and so the higher value
should be used.

Salt dosage required per single softener for 36000 g is 90 kg (from Table 4).

Now looking at Table 5 we find that only wet salt can be used. However, when your
calculated salt dosage allows you the choice of either dry or wet salt always choose dry salt.

Install the brine valve as shown in Brine Tank Set-up.

The initial salt load as shown in Table 7 should be loaded into the brine tank.

IMPORTANT NOTE:

The water softener, as supplied, has the brine riser pipe assembled to suit dry salt
brine system.  If, however, on reference to Table 5 you find that wet salt must be
used, then wet salt brine rise pipe (short black pipe piece supplied) must be fitted to
the brine valve.

Note

:  For wet salt it is very important that the salt level be maintained in line with the

brine valve. As illustrated in the brine tank setup sheet, the salt used per
regeneration must be replenished at least 4 hours before the next regeneration.

Содержание AS36700

Страница 1: ...NSTRUCTIONS Model AS36700 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for commercial industrial...

Страница 2: ...e assembled and installed in the Softener Tank Step 3 Place a 40mm or 50mm plastic pipe through the top hand hole that will reach to the bottom of the softener tank Carefully pour the underbed gravel...

Страница 3: ...ntact our office The brine valve is supplied factory fitted with a dry salt riser a wet salt riser is also supplied short black screwed riser pipe refer Fig 19 Store the riser tube not used DO NOT DIS...

Страница 4: ...d be a 3 pin 10a 240v 50Hz GPO preferably earth leakage protect Total power draw 13 watts maximum i Minimum operating pressure 205 kPa 30psi maximum operating pressure 690 kPa 100psi If supply pressur...

Страница 5: ...erations thus C N H x Q Where C maximum capacity of unit as grams of CaCO3 24000 grams H hardness of water a mg l or ppm Q amount of water passed through the unit in kilolitres per day N maximum time...

Страница 6: ...nstall the brine valve as shown in Brine Tank Set up The initial salt load as shown in Table 7 should be loaded into the brine tank IMPORTANT NOTE The water softener as supplied has the brine riser pi...

Страница 7: ...to allow the brine to saturate Depress the red knob and turn anti clockwise to start release the unit will now go through each cycle Backwash brine rinse purge and back to service automatically the f...

Страница 8: ...you should take into account the working days for instance if the installation will only work week days regeneration on Friday and Monday would be a needless waste of salt Always set in accordance wit...

Страница 9: ...ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bottle Add one 1 tab...

Страница 10: ...Pa A water hammer arrester should be installed if water hammer prevails FAILURE TO OBSERVE WARNINGS WILL VOID WARRANTY Table 3 Model No Capacity Salt Dosage Service Flow Rate Pipe Size Resin Volume Ap...

Страница 11: ...um Medium Maximum litres grams kg grams kg grams kg AS36700 700 24500 45 36000 90 49000 168 Salt Dosage Brine Tank Size kg 1070 x 1220 Dry Wet 32 270 110 40 335 135 50 420 170 55 460 185 65 545 215 75...

Страница 12: ...Page 12 BRINE TANK SETUP...

Страница 13: ...Page 13...

Страница 14: ...Page 14 Series 172 Commercial Industrial Control System Water Softener...

Страница 15: ...Figure 6 Keep in this position for 5 minutes This allows the tank to return to line pressure and permits easier movement of the valve discs 9 Fill the brine tank with the proper amount and type of sa...

Страница 16: ...pause for at least 5 minutes or until tank is pressurised Final check out 1 Test for soft water from a convenient soft water tap 2 Manual by pass valve must be closed see Figure 2 3 Manual inlet and...

Страница 17: ...Page 17 1 INLET 2 BRINE 3 BACKWASH 3 BACKWASH 6 OUTLET 5 BY PASS 4 DRAIN VALVE CLOSED VALVE OPEN VALVE DISC PUSH PULL ROD Flow Diagrams...

Страница 18: ...Page 18...

Страница 19: ...Page 19...

Страница 20: ...No 3 will give a pressure signal during BACKWASH cycle and pressure TAP No 7 will give a pressure signal throughout the entire REGENERATION cycle Before attaching a 6 2 mm tube to any pressure tap dr...

Страница 21: ...d 6 150 cm 3 wire with plug Electrical Connection 1 2 1 3 cm conduit opening Terminal strip inside Standard plumbing connection 2 in NPT inlet outlet top and bottom of tank 1 1 2 NPT drain Union type...

Страница 22: ...Page 22...

Страница 23: ...bulletin 172 O M 3 With Parts No 172D45 and 172D46 together insert Nos 22A354 001 and 172D44 as shown 5 Assemble the 172B36 gear to the 172B39 support so that the deepest of the four slots in the sle...

Страница 24: ...Page 24 REPLACEMENT PARTS...

Страница 25: ...ly 1 6H 2 Valve Disc 2 1 29H Screw Timing Gear 2 6H 2 Valve Disc 3 4 3 30H Screw Pilot Valve 5 6H 4 Valve Disc 5 1 31H Pilot Valve Body Connection 1 7H Screw 26 33H Screw Small Cap Top 4 8H 1 Cap Larg...

Страница 26: ...ipper wheel assembly 1 87F Spring 1 14F 7 7 Day skipper wheel assembly 1 99F 3 6 Day tripper gear 1 85F Screw 2 99F 4 7 Day tripper gear 1 89F Plastic washer 1 120H Motor specify voltage frequency 1 1...

Страница 27: ...low a As in steps a through e above b Increase toward 62 minute time Intermittent brine draw a Low pressure b Clogged injector screen a Set up pressure b Clean or replace as required Hard water after...

Отзывы: