Page 11
Peak flow not recommended for extended periods of time.
Brine Tank:
1000 litre L.D.P.E. moulded construction
complete with lid.
Brine Valve:
Plastic construction.
Operation Pressure:
210 - 600 kPa
Temperature:
5 - 50 degrees C
Electrical:
240v 50Hz 3w maximum
WARNING:
A pressure reduction valve should be installed in areas of high water
pressure (above 690 kPa).
A water hammer arrester should be installed if water hammer prevails.
FAILURE TO OBSERVE WARNINGS WILL VOID WARRANTY
Table 3
Model
No.
Capacity
&
Salt Dosage
Service Flow
Rate
Pipe Size
Resin
Volume
Approx.
Shipping
Weight
Space
Requirements
Minimum
Maximum
Peak
Flow
Continuous
Flow
Inlet
Outlet
Drain
Litres
wt/kg
W x D x H
grams/kg
grams/kg
l/m
l/m
mm
mm
metres
AS30400
14000/26
28000/96
350
265
50
40
400
830
1.8x1.2x2.6
PERFORMANCE DATA
MEDIA LOADING
Model
Underbed Gravel No.6
Resin Content
Brine Tank Gravel No.4
kg
litres
kg
AS30400
120
400
120
Содержание AS30400
Страница 13: ...Page 13 BRINE TANK SETUP...
Страница 14: ...Page 14...
Страница 15: ...Page 15 Series 172 Commercial Industrial Control System Water Softener...
Страница 19: ...Page 19...
Страница 20: ...Page 20...
Страница 23: ...Page 23...
Страница 25: ...Page 25 REPLACEMENT PARTS...