It  is  recommended  that  the  softener  be  now  given  a  regeneration  so  as  to  pre-clean 
the resin bed.  Before this is done proceed as follows: 

 

  Turn power off 

 

  Make sure inlet water to softener valve is “OFF”, outlet valve “OFF” and bypass open 

 

  Verify that drain line is fitted and that there is an “AIR GAP”  between the drain pipe and 

waste hole. 

 

  Remove “VALVE COVER” by pushing the tab, (at rear  of the cover at the left hand back 

corner) backwards 

 

  The valve camshaft is now evident 

 

Slowly turn the camshaft anti-clockwise so that the last two cams (at the far emd) are 
just riding on the two narrow brass ends are now pushed over to the right hand side.  
The valve is  now in the “BACKWASH POSITION”  
 

  Slowly open the mains inlet valve.  Do not open fully, just enough that air and water will 

be  discharged  at  the  drain.    When  no  more  air  is  being  expelled  along  with  the  water, 
close off the mains water inlet valve. 

 

  Slowly  turn  the  camshaft  anti-clockwise  till  the  white  line  in  the  round  window  comes 

around to the “REFILL” position. 

 

  Turn on the “POWER”.  The display will show ‘E r r 3” and the control will advance the 

camshaft by itself around to the “REGENERATION COMPLETE” position (this may take 
up to 5 minutes) and the “E r r 3” being displayed will then revert back to the “TIME OF 
DAY”/”CAPACITY”  green light alternating. 

 

  Once the display green light is alternating  

 

Pour 10-12 litres of water into the brine tank or cabinet.  This is an initial amount of 
water utilised for the first regeneration. 
 
Open mains water inlet valve 
 
Press the large “REGENERATION” button and hold for approximately two seconds 
 
The  green  light  will  now  be  against  “REGEN  TIME  REMAINING”  which  is  the  time 
that  the  softener  is  in  the  regeneration  mode  and  will  decrease  till  the  softener 
completes  the  regeration.    During  this  time  the  controls  green  light  will  alternate 
between “TIME OF DAY” and “REGEN TIME REMAINING”. 
 
 

þ

 

þ

 

þ

 

þ

 

þ

 

Содержание AS1375MP-960

Страница 1: ...ON OPERATING INSTRUCTIONS Model AS1375MP 960 Serial No Telephone 07 3219 2233 Facsimile 07 3219 2266 Email sales ibcwater com au Website www ibcwater com au FILTRATION WATER TREATMENT PRODUCTS for com...

Страница 2: ...25 12 75 93 0 85 0 60 1 6 Peak flow not recommended for extended periods of time Brine Tank Poly moulded or fibreglass construction complete with lid Brine Valve Plastic construction Operating Pressur...

Страница 3: ...H THE TOP STRAINER SUPPLIED LOOSE IT IS IMPORTANT THAT THIS STRAINER IS ASSEMBLED TO THE VALVE DURING INSTALLATION THE LENGTH OF THE INTERNAL RISER PIPE IS FACTORY ADJUSTED FOR THE TANK SIZE PROVIDED...

Страница 4: ...rogramming For your Application Units of Measure Notes P1 Time of day AM or PM 1 00 to 12 59 1 Current time Hour minute Range depends on value selected for P13 Enter the current time P2 Time of day Of...

Страница 5: ...erous to walk on STEP 5 Clean top of neck and threads of all traces of resin Remove the plastic cap fitted in Step 3 taking care not to raise the distributor pipe NEVER shorten the length of the distr...

Страница 6: ...nded The following will have to be programmed into the control Current time of day Hardness of your local water supply Plug transformer into main GPO Push lead end into socket underneath the front of...

Страница 7: ...k Using the buttons key in the current second hour figure In example 11 25 Key in 1 Press the key the first hour digit will blink Using the buttons key in the first hour figure In example 11 25 Key in...

Страница 8: ...k Using the button only keep on pressing slowly until a little dot appears in the top left hand corner of the display under PM if the display is blinking and shows 1 keep on pressing button until 0 ap...

Страница 9: ...ck the settings in the program wait till the green light moves to TIME OF DAY Check time of day is correct Press button to TIME OF REGENERATION 2 00 should be displayed Press button to HARDNESS the ha...

Страница 10: ...r is being expelled along with the water close off the mains water inlet valve Slowly turn the camshaft anti clockwise till the white line in the round window comes around to the REFILL position Turn...

Страница 11: ...brine tank or cabinet will be refilled with the correct amount of water necessary to dissolve the salt required Open the outlet mains valve and close off the bypass valve and check the treated water a...

Страница 12: ...AS1375MP 960 Page 12 20 11 2006 Water Conditioning Control System Installation Operating and Maintenance Manual Series 255 Valve 960 Control...

Страница 13: ...neration Manual Regeneration Care of Your Water Conditioner 20 General Cleaning the Injector Injector Screen Maintaining the Drain Line Manual Valve Operation 22 Additional Features 22 Disinfection of...

Страница 14: ...ree performance The metering system has only one moving part a rotating turbine that measures water usage Time and Capacity Display During normal conditioning operation the correct time of day alterna...

Страница 15: ...held closed by water pressure and are leak tight Valve seats are in a vertical position which is the position least vulnerable to plugging System operation cannot get out of phase or sequence The cont...

Страница 16: ...s Water Line Connection A bypass valve system must be installed to provide for occasions when the water conditioner must is by passed for hard water or for servicing The most common bypass systems are...

Страница 17: ...y freezes with the REGEN TIME REMAINING information After the first regeneration is completed the second regeneration begins immediately The display will alternate between the TIME OF DAY and REGEN TI...

Страница 18: ...ing a regeneration of the water conditioner Time of Regeneration can be set for any time AM or PM Note The control may be programmed for an immed iate regeneration option In this case the control does...

Страница 19: ...bers until you reach the desired setting 5 Press the SET button The number stops flashing and the control accepts the new setting After approximately 30 seconds the control starts alter nating the dis...

Страница 20: ...his setting your dealer has disabled it Some municipalities require that the Salt Setting not be adjustable Contact your dealer for additional information Capacity Setting The Capacity Setting refers...

Страница 21: ...in this manual or contact your dealer for more information about these options The factory setting for Time of Regeneration is 2 00 AM You can change this time Refer to the Time of Regeneration sectio...

Страница 22: ...caution note 12 Reinstall cover reconnect electric power and reset the time of day 13 Slowly open the water supply valve or return the bypass valve s to the not in bypass position Maintaining the Drai...

Страница 23: ...ption is a method of forcing the control to regenerate after a preset number of days is normal demand based regeneration does not occur first This feature is not set at the factory your dealer can set...

Страница 24: ...sed to treat potable water Refer to the Disinfection of Water Conditioners section in this manual Complete the following steps to place the conditioner into operation 1 Remove the rear valve cover by...

Страница 25: ...ts refer to the Troubleshooting section in this manual When the water is being drawn fro the brine tank rotate the camshaft COUNTERCLOCKWISE until the indicator points to REGEN COMPLETE Run water from...

Страница 26: ...r Tank 1000215 No 14 for 14 in Diameter Tank 7 1030502 Ball Flow Control 1 8 Injector Assy With O rings 1 1032970 A Injector White 1032971 B Injector Blue 1032972 C Injector Red 9 Injector Cap With O...

Страница 27: ...AS1375MP 960 Page 27 20 11 2006 C Meter Adapter Bypass Valve and Piping Boss Bypass Valve 3 960 Control...

Страница 28: ...611 3 4 in BSPT Brass Pipe Adaptor Kit 1 1001610 1 in NPT Brass Pipe Adaptor Kit 1 1001612 1 in BSPT Brass Pipe Adaptor Kit 1 Not Shown Code Part No Description Qty Piping Boss 1 Kit Piping Boss Inclu...

Страница 29: ...ic Failure Improper start of regeneration limit switch closed when it should be open Improper finish of regeneration limit switch open when it should be closed Improper control settings Cause Control...

Страница 30: ...Loss of power to the system a Transformer unplugged b Fuse blown circuit breaker open or circuit switched off a Connect the power b Correct the electrical problem 4 Control does not regenerate automa...

Страница 31: ...alent Manual Regeneration Guest Cycle Forces the control to regenerate by pressing the REGEN button Regeneration Includes the backwash brine draw and fresh water rinse steps necessary to prepare the r...

Страница 32: ...AS1375MP 960 Page 32 20 11 2006...

Страница 33: ...f approximately 20ppm based on a sample volume of 10mls Other hardness test kits are available for more accurate testing eg Hardness Tablets Directions Take a 50ml sample of water in a screw capped bo...

Отзывы: