Fire precautions 

 

Please contact the local authorities to determine the fire prevention regulations and 
requirements for homes and buildings. 

 

Roof constructions and installations can affect a building's fire resistance. Defects in these 
areas can pose fire hazards. 

 

When installing modules on the roof, they should be mounted on a fire resistant covering (or 
surface) that is approved for this purpose. 

 

Components such as ground fault switches, fuses, and circuit breakers may be required. 

 

Do not place the modules near equipment or areas where gas is produced or can 
accumulate. 

 
 
 
Electrical installation 

 

When installing, wiring, operating, and maintaining the module, take all required 
precautionary measures to prevent electrical hazards. 

 

In the case of module or phase voltages of more than 120 V, the extra-low voltage range is  
left. Undertake the necessary protection and cautionary measures. Installation, handover, 
and maintenance must be performed by a licensed electrician unless the local ordinances 
require any other measures for handling electrical systems. 

 

Contact with DC voltage of 30 V or more is potentially dangerous. 

 

Do not install modules with different electrical parameters or physical specifications within 
the same system. 

 

The system's maximum open-circuit voltage must not exceed the module's maximum rated 
system voltage. 

 

All IBC SOLAR AG modules are equipped with factory installed connecting cables and 
plugs. Their design allows them to be easily installed in series. 

 

IBC SOLAR AG modules of series PolySol TX are equipped with Multi-Contact® type 4 
snap-in connectors. The PV module's plug connection can also be protected using the 
pluggable PV-SSH4 safety lock clip available from Multi-Contact®. 

 

The PV-SSH4 clip is not supplied by IBC SOLAR AG and must be purchased separately. If 
the lock clip is installed, the PV module's plug connection can only be unlocked using the 
PV-MS tool, which is also available from Multi-Contact®. 

 

Make sure to use suitable cross-sections and connections that are approved for the 
module's maximum short-circuit current when wiring the system. 

 

When establishing the connections, make sure the polarities of the cables and connection 
terminals are correct. Otherwise, there is a risk of damaging the module. 

 

If the reverse current can exceed the maximum fuse rating specified on the module rear, a 
properly approved and certified over current blocking device (fuse or circuit breaker) must 
be installed in series with each module or each module string both in the positive as well as 
the negative pole of the generator. 

 

The rated power of the over current blocking device must not exceed the maximum fuse 
rating specified on the module rear. 

 

The module is equipped with factory installed bypass diodes that are located inside the 
junction box. 

 

The junction box is not suitable for modification during installation and must never be 
opened. If the junction box is opened, the module warranty will become void. 

 

Modules suspected of having electrical problems should be returned to IBC SOLAR AG for 
inspection and if necessary, repair according to the warranty conditions of IBC SOLAR AG. 

 

Warning: Connecting modules in reverse polarity to a high current source, such as a 
battery, will destroy the bypass diodes. This will render the complete module inoperative. 
Bypass diodes cannot be replaced by the user. 

 
 

Содержание PolySol TX Series

Страница 1: ...aling as little as 5 of full sunlight The current and power output increase with the light intensity The output power generated by the modules may exceed the specified rated power The rated values are...

Страница 2: ...tective equipment Safety precautions during installation Make sure that no children or other persons are near the systems or modules during installation Do not perform installation work under severe w...

Страница 3: ...n connectors The PV module s plug connection can also be protected using the pluggable PV SSH4 safety lock clip available from Multi Contact The PV SSH4 clip is not supplied by IBC SOLAR AG and must b...

Страница 4: ...he inverter manufacturer Mechanical installation The modules should be mounted so that they are exposed as directly to sunlight as possible and to as little shading as possible Even partial shading ca...

Страница 5: ...r to take into account the thermal linear expansion of the module frame the distance between 2 modules should be 20 mm However it has to be at least 10 mm For mounting with clamps the surface pressure...

Страница 6: ...Commission a specialist company for this purpose IBC SOLAR AG is a member of the European PV Cycle Association and accepts our product responsibility You can give back modules of IBC SOLAR AG and all...

Страница 7: ...Appendix 1 Clamping range long side...

Страница 8: ...Appendix 2 Clamping range short side Attention For using clamps at the short side the max load must not exceed 2400 Pa...

Отзывы: