88
MPT-3000V User Manual
⚫
Setting CB Good
Parameter:
SET_CB_GOOD
Sets Power Good voltage for car battery.
Request:
Header Size Command
Data0
Data1 CRC
0xFF
0xEE
0x02 SET_CB_GOOD
High
Byte
Low
Byte
Reply
Header Size
Command
Data
CRC
0xFF
0xEE
0x00 SET_CB_GOOD
None
Round off to the 1
st
decimal place.
Ex. Setting 11.2V mapping to 11200 (11.2 x 1000) = 2BC0 (hex)
Data0 = 2B (hex)
Data1 = C0 (hex)
⚫
Setting PB Good
Parameter:
SET_PB_GOOD
Sets Power Good voltage for UPS battery.
Request:
Header Size Command
Data0
Data1 CRC
0xFF
0xEE
0x02 SET_PB_GOOD
High
Byte
Low
Byte
Reply
Header Size
Command
Data
CRC
0xFF
0xEE
0x00 SET_PB_GOOD
None
Round off to the 1
st
decimal place.
Ex. Setting 11.2V mapping to 11200 (11.2 x 1000) = 2BC0 (hex)
Data0 = 2B (hex)
Data1 = C0 (hex)