background image

 

 

 

 
 
 

 
 

 

 

 

 
 
 
 

 
 

 

 
 
 
 
 
GENERAL CHARACTERISTICS AND DIMENSIONS 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Optionally and on request, models 30 and 50 AR-A INOX can be fitted with supports 
for wall and/or floor anchoring. Both covers have a central hole (P - V) and trim, leaving 
both sleeves accessible. They are supplied uncapped

.

 

AR-A STAINLESS STELL PUFFER TANKS 

Model 

30 AR-A INOX 

50 AR-A INOX 

Model Code 

30003061 

30005061 

Nominal capacity (Litres) 

30 

50 

Maximum service pressure (Bar) 

Temperature (ºC) 

-10 / +100 

-10 / +100 

Thermal insulation  

PU rigid 

PU rigid 

Insulation thickness (mm) 

25 

25 

External finish 

Embossed 
Aluminium 

Embossed 

Aluminium 

Chocks with adhesive 

Yes  

Yes 

ErP 

C  

C  

Weight (Kg) 

15 

Connections

 

e

f

 /e

c

: lateral inputs 

2x1” G.H 

2x1” G.H 

r

f

 / r

c

: lateral exits 

2x1” G.H 

2x1” G.H 

v: Upper 

½” G.H. 

½” G.H 

p: Lower 

½” G.H. 

½”

 

G.H. 

t: thermometer 

½” G.H. 

½” G.H. 

s: Auxiliary 

-- 

½” G.H. 

s`: Auxiliary 

½” G.H. 

½” G.H. 

Dimmensions (mm)

 

ØD: Diameter ext. 

410 

410 

H: Total height 

460 

560 

145 

180 

305 

380 

C  

145 

165 

-- 

325 

F  

305 

415 

Accessories 

Reference

 

 

Support kit 

(*)

 

19011052 

30 - 50 AR-A INOX 

Vertical installation 

above ground (chocks) 

 

Wall installation  

with supports 

 

Horizontal installation 

with supports 

 

Horizontal installation 

on supports 

 

 

Содержание 30 AR-A INOX

Страница 1: ...ILLELA AUZOTEGIA 48100 MUNGIA SPAIN APDO CORREOS 21 C I F A 48045199 Tlf 34 94 674 04 00 www ibaiondo com Stainless Steel puffer Tanks Refrigeration Heat Pump Closed Circuit Installation instructions use and maintenance ...

Страница 2: ...nd that the correct operating instructions are enclosed It is especially important to check the buffer tank for possible deformations that could affect its resistance If defects or damage are found contact the manufacturer immediately Check that the data on the sticker affixed to the buffer tank matches the purchase specification and is suitable for the installation Before proceeding with the inst...

Страница 3: ...ng to DIN 4753 part 1 section 6 3 4 2 must be read on the safety relief valve During the heating phase for safety reasons water may escape from the exhaust duct Keep the exhaust pipe open Safety valve evacuation pipeline The evacuation of boiling water and steam must not endanger people The discharge lines of 2 or more safety valves must lead freely and separately to a drainage point The exhaust d...

Страница 4: ...are parts This is an indicative layout It is never a substitute for an expert s project 7 Filling Make sure that the hoses and couplings of the system are watertight Check all connections of the accumulator for tightness and closure All connections that are not to be used must be properly plugged Proceed with the flushing of the pipelines according to DIN 1988 Fill the puffer tank and drain it Fil...

Страница 5: ...valve s activation pressure and functionality Check expansion vessel pre charge Check the working pressure values and pressure fluctuations Verify temperatures 9 Declaration of Conformity INDUSTRIAS IBAIONDO S A with VAT number A48045199 and address at Plentzia bidea nº3 48100 Munguia Vizcaya declares that the models contained in this document have been designed and manufactured in accordance with...

Страница 6: ...insulation PU rigid PU rigid Insulation thickness mm 25 25 External finish Embossed Aluminium Embossed Aluminium Chocks with adhesive Yes Yes ErP C C Weight Kg 8 15 Connections ef ec lateral inputs 2x1 G H 2x1 G H rf rc lateral exits 2x1 G H 2x1 G H v Upper G H G H p Lower G H G H t thermometer G H G H s Auxiliary G H s Auxiliary G H G H Dimmensions mm ØD Diameter ext 410 410 H Total height 460 56...

Страница 7: ...t to run from the date of delivery by IBAIONDO The warranty does not apply if the defect is due to misuse of the product non prescribed use improper handling if the maximum pressure and or temperature values have been exceeded or in general if any of the instructions for commissioning use or maintenance included in the documentation provided have not been followed IBAIONDO is not responsible for d...

Отзывы: