background image

ibaPADU-8-ICP 

Parallel A/D Converter Unit for Fast Measurement with ICP Sensors 

 
 

Manual 

Issue 1.7 

Содержание PADU-8-ICP

Страница 1: ...ibaPADU 8 ICP Parallel A D Converter Unit for Fast Measurement with ICP Sensors Manual Issue 1 7...

Страница 2: ...e is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be downloaded on the Internet The current ve...

Страница 3: ...pply Connection 13 7 2 2 Fiber optic Ports RX and TX 13 7 2 3 Setting the Device Address with S1 and S2 Decade Switches 13 7 2 4 Terminal Blocks Pin Connections X1 X5 X14 13 7 2 5 Run Link and Error L...

Страница 4: ...1 5 Output Resources for iba FOB M FOB M Out 28 10 1 6 Control of ibaPADU 8 ICP in ibaLogic application program 29 10 1 7 Data Buffer Size 30 10 2 Configuring with ibaPDA 30 10 2 1 Configuring ibaPAD...

Страница 5: ...lectronic modules as well as communication and measurement technology A person is regarded to as professional if he she is capable of assessing safety and recognizing possible consequences and risks o...

Страница 6: ...ol function The non observance of this safety information may result in a potential risk of death or severe injury The non observance of this safety information may result in a potential risk of injur...

Страница 7: ...ovides a maximum of 4x96x8 3072 analog and digital measurement channels Each analog channel can be connected di rectly to ICP type sensors without interposing signal conditioning ICP sensors must meet...

Страница 8: ...applications Measurement data logging and analysis Applications of ibaSoftware products ibaLogic ibaPDA V6 etc The device may not be operated in mains supply circuits 4 2 Special advices Important no...

Страница 9: ...ollowing cards ibaFOB io S or ibaFOB 4i S ibaFOB 4o ibaFOB io D or ibaFOB io Dexp ibaFOB 2io D or ibaFOB 2io Dexp ibaFOB 4i D or ibaFOB 4i Dexp and ibaFOB 4o ibaFOB io ExpressCard for notebook 5 2 Sof...

Страница 10: ...to applying power 4 Connect fiber optic cable to the TX RX ports as shown on the device so that the fi ber optic ring is completed 6 2 Dismounting 1 Disconnect the power supply 2 Disconnect all cables...

Страница 11: ...as well as multiplexing of up to 96 devices Programmable sampling frequency period minimum 500 Hz 2 msec maximum 25 kHz 40 s sampling period increment of 50 nanoseconds 8 analog inputs with ICP senso...

Страница 12: ...port X11 24 V DC Power Connector X14 TX port X10 Address Switches S1 S2 1 96 ICP inputs 00 03 X1 binary inputs connector LEDs L4 L11 binary inputs connector 00 07 X5 ICP inputs 04 07 X1 Top View Seri...

Страница 13: ...the Device Address with S1 and S2 Decade Switches Using a precision screwdriver or other suitable instrument turn the S1 decade switch to the ones digit of the desired device address and then turn th...

Страница 14: ...f power is on and device is healthy no power Link yellow Off On Blinking No incoming data stream PC is inactive or the previous device in the chain is defective data is being received at RX not active...

Страница 15: ...o be removed or apply 5 V to the bootpin and the device has to be rebooted The device is now booting with the new firmware Under normal service conditions the V 24 cable must not be connected Service...

Страница 16: ...dividual iba FOB interface must be con nected to the RX port on the first ibaPADU 8 ICP in the fiber optic ring Installed devices may be in terconnected in any order con secutive addresses are not re...

Страница 17: ...n of the device network is not required Figure 2 Star Topology If an ibaPADU 8 ICP is connected with a fiber optic link of an ibaFOB card no other PADU type can be connected to the same link But it is...

Страница 18: ...The selection of the devices which signals shall be captured can be automatically done in iba Logic or manually in ibaScope or ibaPDA If an ibaPADU 8 ICP is con nected with a fiber optic link of an ib...

Страница 19: ...that is requested via an ibaFOB telegram the device returns the ac tual gain setting when measurements begin Table 1 Possible Input Gains 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 0 5 dB step area 5 0 5...

Страница 20: ...aximum signal strength Therefore the analysis software should take this into account Tip At corner frequencies 1000 Hz reflected frequencies above 50x the corner fre quency are possible Example 1 fc 1...

Страница 21: ...ms show the characteristics of the used programmable input filter The filter itself causes a delay within the ibaPADU 8 ICP This delay is named Group delay At an edge frequency of 1 kHz this delay is...

Страница 22: ...ith ibaScope please refer to the ibaScope manual 10 1 Working with ibaLogic V3 With ibaLogic you may analyse 25 kHz signals By using additional slow process va riable you may define monitoring ranges...

Страница 23: ...h the major part of iba de vices such as PADU 8 16 32 ibaLink SM 64 io ibaLink SM 128V i 2o ibaNet750 BM etc The fastest sample rate is 1 kHz 1 ms You may use ibaPDA ibaLogic or ibaScope as software a...

Страница 24: ...Settings Instead of the Apply button you will find the button Save configuration which in fact has the same function There is a second button Configuration FOB M in the dialog System Settings FOB IO F...

Страница 25: ...s of this type and the LEDs showing the status of every link The physical connection is ok if the green LED is flashing and the yellow LED is on Telegrams are received by ibaPADU 8 ICP and the communi...

Страница 26: ...call the Padu setup dialog window by clicking on the button Setup Padu M Other documentation For a more detailed description of the diagnostic functions and parameters please re fer to the ibaDiag ma...

Страница 27: ...e in s Actual gain of the channels in dB for channels 1 8 Actual corner frequency of low pass filter for channels 1 8 Actual reset status Actual command beeing processed Measured values of analog chan...

Страница 28: ...After parameterization the device sends a continuous data stream to iba Logic Please note further that the change of parameters may affect the processing of other in and output resources due to a hal...

Страница 29: ...requency for each channel to be used The val ues depend on the measurement arrangement and sensor types For the supply of the other parameters iba developed a sample function block FOBM_Control which...

Страница 30: ...c e g 25 ms 1 25 ms x 2050 82 000 values sec channel Data read rate DRR 1 40 s 25 000 values sec channel Data generation rate DGR Note The data read rate must be at least three times the data generati...

Страница 31: ...device is connected correctly to this link the autodetect feature will find it and place modules Padu 8 ICP on this link Right click the link of the FOB D or FOB S card to which the ibaPADU 8 ICP is...

Страница 32: ...umbers automatically in a chronological order However you may prefer a different order later in the data file for analysis The module number determines the order in the signal tree in ibaAnalyzer Time...

Страница 33: ...vice address address 0 95 according to the rotary switch settings S1 and S2 4 you can enter signal names and see actual values Define the signal parameters After selecting the tab Analog The unit is p...

Страница 34: ...dropdown menu You can also display other signal properties in the grid with a right mouse click on the headline of the grid In the same way you can parameterize the digital signals 5 To finish the co...

Страница 35: ...dialog to create the expressions for the triggers The trigger builder is based on the ibaScope trigger editor Open the trigger builder by clicking on the expression builder icon of the digital sig nal...

Страница 36: ...Manual ibaPADU 8 ICP 36 Issue 1 7 The custom tab contains the regular expression builder Finish the definition of one trigger event with OK Define further trigger events in the same way...

Страница 37: ...s then the trigger pool fires The trigger can fire on a rising edge of the trigger signals or it can fire each sample the trigger signal is 1 If you want to use a trigger pool as a trigger then you ha...

Страница 38: ...eed as follows 1 Activate and name the data store 2 Define the Start Stop Trigger Either as a single trigger event or one or more events from the trigger pool see above 3 Define the signals to store 4...

Страница 39: ...you are in the ibaPDA client main view Mainly ibaPDA has three view types The trend graph the Scope view and the FFT view Click to the icons to create the views in the signal monitor and place the do...

Страница 40: ...ble up to 25 kHz 8 channels simultaneously FO cable Coupling 62 5 125 m ST Lean Max length of fiber optics between devices 2000 m 6560 ft Dimensions WxHxD mm inch 54 x 194 x 155 2 13 x 7 64 x 6 10 Wei...

Страница 41: ...specify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 Email iba iba ag com Contact Mr Harald O...

Отзывы: