Signal
Description
BufferOverrun
Counter for Buffer-overrun
Additional output signals for buffered access
BufferSize
Buffersize
SubSampling
Subsampling of the signals
9.2.2
Configuring input gain
If you want to use gain factors, these are made as configuration output and configured
as Off-task connector (OTC) or function block.
First, drag the output signals defined in the I/O configurator to the margin of the program-
ming surface, in this example “X2_Gain_Ch00” for the analog input 0.
Figure 13: Output signal on the margin
Create a new Off-task connector in the programming window, assign a meaningful name
to the connector, e.g. “Gain” and choose “Input” and Data type “UINT” under the Con-
nector type option.
Figure 14: Editing Off-task connector
Meaning of the default values for the input gain:
0 gain switched off
6 gain = 6 dB
12 gain = 12 dB
20 gain = 20 dB
Now, connect the OTC and the signal on the margin of the programming surface.
Figure 15: Connecting Off-task connector