![IBA ibaFOB-2i-D Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/iba/ibafob-2i-d/ibafob-2i-d_manual_604351040.webp)
Manual
ibaFOB-D
40
Issue 1.11
8.2
Configuration of output modules
8.2.1
Introduction
For a number of devices, it is possible to transmit signals from ibaPDA to a device via
the FOB output channel. These output signals are mainly intended to signal events or to
trigger alarms or warnings. Analog values can also be output. The configuration is carried
out in ibaPDA in the I/O Manager.
On the device side, you need a device that is suitable for processing output signals, e.g.
ibaNet750-BM with WAGO output terminals or an ibaPADU-S-CM device with one or
more output modules.
An ibaFOB board with FO-output links is required on the computer side. The outputs are
either the integrated outputs on the board (io and 2io) or the outputs when an extension
module ibaFOB-4o (-PCI/-Rackline slot) is connected as an output board.
Below you find a list of the interface boards that can be used for digital and analog output
and their corresponding output modules.
Interface board
Output modules
Note
ibaFOB-io-S, -X, -D/-Dexp
(inkl. FOB-2io-, 4i+4o)
ibaFOB-io-ExpressBoard
ibaFOB-io-USB
FOB alarm
ibaNet750-BM
Only available when borad is plugged
in
FOB link in 3Mbit mode
ibaFOB-io-D/-Dexp
(inkc. FOB-2io-, 4i+4o)
ibaFOB-io-ExpressBoard
ibaFOB-io-USB
ibaPADU-S-CM
ibaPADU-S-IT-2x16
ibaPADU-S-IT-16
HAICMON CMU
ibaCMU-S
ibaPQU-S
ibaBM-DP
ibaBM-PN
ibaLink-io-embedded
ibaLink-VME
ibaNet750-BM/-BM-D
Generic Flex
Only available when borad is plugged
in
FOB link in 32Mbit Flex mode
Which output modules you can use depends not only on the devices used but also on
the communication mode used at the FO link.
In 3Mbit mode only the output modules "FOB alarm" and "ibaNet750-BM" (with corre-
sponding output terminals) can be used.
Most current devices, such as ibaPADU-S-CM or ibaBM-DP, only support the output
function in 32Mbit Flex mode.
In 32Mbit mode no output modules are available.