Installation, Connection, Disassembly 

6.1 

Installation 

1. 

Insert the clip of the mounting rail fastened on the device into the mounting rail. 

2. 

Press the device down in such a way that the clip of the mounting rail engages with 
a click. 

6.2 

Connection 

1. 

If it is stipulated for the system that the device must be grounded, connect it to earth. 

2. 

Connect the power supply. Observe the correct polarity. 

3. 

Connect the fiber optic cables to the inputs and outputs. 

4. 

If you have connected all the required fiber optic cables, switch on the device. 

 

 

Note 

The device will immediately switch into ready-for-operation mode. The LED L1 is blink-
ing. 

During current operation you are able to perform operations on the device. The device 
can remain switched on. 

 

6.3 

Disassembly 

 

 

Note 

If the power supply is interrupted, the device is no longer ready for operation. No LEDs 
are lit up or blinking. 

 

1. 

Switch off the device. 

2. 

Disconnect the power supply. 

3. 

Disconnect it from the earth. 

4. 

Disconnect all FO cables. 

5. 

Close the open inputs and outputs with a cover. 

6. 

Hold the device to prevent it from falling down and press it slightly downwards. 

7. 

After that pull the device and lift it up. The clip of the mounting rail will disengage with 
a click. 

8. 

Remove the device. 

When  storing  or  transporting  the  device  observe  the  values  specified  in  the  chapter 
“Technical data”. 

Содержание 13.114100

Страница 1: ...Data distributor ibaBM DIS i 8o Manual Issue 1 2...

Страница 2: ...ll compliance is not guaranteed However the information in this publication is updated regularly Required corrections are contained in the following regulations or can be down loaded on the Internet T...

Страница 3: ...8 4 2 1 Copy mode 8 4 2 2 Distribution mode 9 4 2 3 Copy and cut mode 9 4 3 Certificates 10 4 4 Device views 10 4 4 1 Front view 10 4 4 2 Top view 11 4 4 3 Bottom view 11 4 5 Indicators 12 4 6 Operat...

Страница 4: ...Manual ibaBM DIS i 8o 4 Issue 1 2 8 Support and contact 21...

Страница 5: ...is capable of assessing safety and recognizing possible consequences and risks on the basis of his her spe cialist training knowledge and experience and knowledge of the standard regulations 1 2 Desi...

Страница 6: ...ess and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non...

Страница 7: ...products The device must not be operated in mains supply circuits 2 2 Designated environment of use The device should only be operated and stored under conditions as described in chapter Technical da...

Страница 8: ...with minimum delay and without any modifica tion All via ibaNet fiber optics transmitted signals of any ibaNet protocol type can serve as an input signal The device automatically detects the type of...

Страница 9: ...ution on 8 output links by ibaBM DIS i 8o Figure 2 Principle of distribution mode 4 2 3 Copy and cut mode In copy and cut mode 1 incoming fiber optic data stream with 32 Mbit s is copied to 8 outputs...

Страница 10: ...s B 4 4 Device views 4 4 1 Front view 1 2 3 4 5 6 7 8 Operating status indicators L1 L4 On off switch S11 Connector for power supply 24 V X14 Rotary switch S1 Connection FO input RX X10 Connection FO...

Страница 11: ...Support iba iba ag com Internet www iba ag com Certification CE FCC Class B Power supply DC 24 V 10 0 2 A Product name ibaBM DIS i 8o Figure 4 Top view 4 4 3 Bottom view Connectors on the device botto...

Страница 12: ...has been detected No 32 Mbit s signal detected L4 Red Blinking Off Error OK 4 6 Operating elements Mode of operation switch Position Mode Description 0 Copy mode All output signals input signal for al...

Страница 13: ...he first 8 bytes of digital data are transmitted Input cycle time 100 s the first 128 bytes of analog data any data type and the first 8 bytes of digital data are transmitted 5 to F Reserved for futur...

Страница 14: ...output Outputs iba devices with 3 3 Mbit s FO input 5 2 Application 5 2 1 Copy mode 5 2 1 1 Connecting a measurement device with 2 or more computers The measured signals from a bus module e g ibaBM DP...

Страница 15: ...plied with the ibaBM DIS i 8o and serves as synchronous source for all FO links It is possible to connect more devices in a row daisy chain Figure 8 Multiplication of synchronization signals e g for i...

Страница 16: ...tances the ibaBM COL 8i o can be used as a collector for up to 8 FO links 3 3 Mbit s Only 1 cable is required for the data transmission over long distance Seven FO cables can be saved On the target si...

Страница 17: ...ce will immediately switch into ready for operation mode The LED L1 is blink ing During current operation you are able to perform operations on the device The device can remain switched on 6 3 Disasse...

Страница 18: ...ut with 2 0 Mbit s 3 3 Mbit s 5 0 Mbit s uni direc tional 32 Mbit s mirrored to 8 1 outputs Distribution mode 1 input 32 Mbit s 1 ms sampling time with 512 digital and 512 analog signals split and dis...

Страница 19: ...ing Passive Operating temperature 32 F to 122 F 0 C to 50 C Storage temperature 13 F to 149 F 25 C to 65 C Transport temperature 13 F to 149 F 25 C to 65 C Orientation Vertical typ Humidity class F no...

Страница 20: ...Manual ibaBM DIS i 8o 20 Issue 1 2 7 2 Dimension sheet Dimensions given in mm Figure 11 Dimension sheet...

Страница 21: ...quire support specify the serial number iba S N of the product Contact Headquarters iba AG Koenigswarterstr 44 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E Mail iba iba ag com Conta...

Отзывы: