background image

IAP Boxair M1002

www.IAP-AirProducts.com

- 7 -

MAINTENANCE

DAILY: 

 

overall control for connection

tightness, including the state of 

chamber door seals and flexible hoses

visual control of the filter wear (how to

access the filter cartridge - page 6)

MONTHLY: 

visual inspection for signs of corrosion

electrical system and wire insulation

control

YEARLY:

 

filter cassette replacement

inspection for corrosion or  any type of

mechanical perforation of the filter box

inspection of electrical wiring

TROUBLESHOOTING

SYMPTOMS

POSSIBLE REASONS

PROCEDURE

Low air volume.

Filter cartridge is clogged.

Take  out  filter  cassette  and  clean  it.  If  this 

proves ineffective replace with a new one.

Obstructed suction channel

Check  the  efficiency  of  channels  and  if 

necessary clean them.

Dust coming out of the filter.

Wrong or mechanically damaged seal or 

filter cassette.

Properly tighten the filter gasket.

Replace filter cassette with a new one.

Cannot start the

device.

No power supply.

Check the connection of the device, check the 

power supply.

EC DECLARATION OF CONFORMITY

The manufacturer:  

Industrial Air P

roducts

2544 Highway 70 East

 

Cookeville, TN 38506

Confirms the following product: 

Boxair M1002 mobile filter unit

meets the requirements of the following European directives:

• 

Directive 2006/42/EC of the European Parliament and the Council of 17 May 2006. on machinery and amending Directive 95/16/EC (recast).

• 

Directive 2006/95/EC of the European Parliament and the Council of 12 December 2006 on the harmonization of the laws of the Member States relating 

to electrical equipment designed for use within certain voltage limits.

and the following standards:

• 

BS EN 60204-1:2010 Safety of machinery - Electrical equipment of machines - Part 1 General Requirements.

• 

BS EN 12100-2:2005 / A1: 2009 EN Safety of machinery - General principles for design - risk assessment and risk reduction.

• 

BS EN 13857:2010 Safety of machinery - Safety distances to prevent reaching the upper and lower limbs to hazardous areas.

• 

BS EN 60034-1:2009 EN Rotating electrical machines - Part 1: Rating and performance

Содержание BOXAIR M1002

Страница 1: ...www IAP AirProducts com BOXAIR M1002 Mobile Filter Unit User s Manual...

Страница 2: ...C SYMBOLS 3 GENERAL INFORMATION 3 PRODUCT APPLICATION 3 EQUIPMENT ARRIVAL 3 CONSTRUCTION 4 DIMENSIONS 4 TECHNICAL DATA 5 ARM INSTALLATION 5 FILTER REPLACEMENT 6 START UP WIRING DIAGRAM 6 MAINTENANCE 6...

Страница 3: ...manent human habitation Boxair M1002 is designed for extraction and purification of air from the dry dust with particular emphasis on the processes of welding grinding polishing pouring dispensing gri...

Страница 4: ...5 A Boxair M1 660 1047 1 660 719 5 160 660 160 660 719 2 A 1 6 C 1 6 www oskarairproducts com info oskarairproducts com Konstrukcja standardowa Parametry Akcesoria i opcje Opis Cz ci zamienne Nazwa ko...

Страница 5: ...minal airflow cfm 700 Noise level dB A 68 Power supply V Hz 1x 120 60 Power rating HP 1 5 Energy usage A 2 7 Rotational speed RPM 2800 Metal mesh prefilter pcs 1 Cassette filter pcs 1 Weight without a...

Страница 6: ...l out of the chamber A 242 177 G2 Prefilter 2000 hours B 242 205 F9 Cassette filter 400 hours Depending on application filter replacement times can differ START UP WIRING DIAGRAM All electrical work m...

Страница 7: ...start the device No power supply Check the connection of the device check the power supply EC DECLARATION OF CONFORMITY The manufacturer Industrial Air Products 2544 Highway 70 East Cookeville TN 385...

Страница 8: ...IAP Boxair M1002 888 372 0050 x4 Sales IAP AirProducts com www IAP AirProducts com...