background image

10 

 

CALIBRATION 

 

 

 

 

 

 

 
User adjustable / factory calibration. 

2vZero  

 

0.01000 

 

Zero counts in 2Vdc mode 

 

 

 

 

Calibration of the 18bit DAC output. 

2vSpan  

 

2.00000 

 

Span counts in 2Vdc mode 

 

 

 

 

Calibration of the 18bit DAC output.

 

10vZero  

 

0.0000  

 

Zero counts in 10Vdc mode 

 

 

 

 

Calibration of the 18bit DAC output.

 

10vSpan  

 

10.0000 

 

Span counts in 10Vdc mode 

 

 

 

 

Calibration of the 18bit DAC output.

 

Out.Vdc 

 

 

 

 

Output monitor Span counts 

 

 

 

 

Calibration of the output DC voltage monitor.

 

Batt.Vdc / DC Inp.Vdc 

Battery / Ext. power supply Vdc Span counts 

Calibration of the Battery & external DC supply 
for the main screen.

 

Charge mA 

 

 

 

 

Charge current Span counts 

 

 

 

 

Calibration of the battery charging current monitor. 

Use the menu options as detailed at the bottom of the screen to navigate the various entries, Quit, Save 
etc. Please note that LOAD.DEF will load pre-set factory settings and NOT your as-shipped custom 
settings. See the Calibration record at the back of this manual for YOUR settings. 

Any changes to settings are saved to EEprom. 

Note: If you decide to make any adjustments to the above settings/calibration then please record the 
original settings before you start. 

 

 

 

Содержание PDVS2

Страница 1: ...CE Model PDVS2 A multitude of uses as a calibrator reference and fully adjustable precision voltage source Handmade in Great Britain by Ian Johnston Manual Version 1 2 27 04 17 Ian Johnston Engineerin...

Страница 2: ...NSTRUMENT 3 MAIN 4 PLAYBACK MODE 5 RAMP MODE 6 COMMS ON OFF 7 2V 10V MODE 8 SETTINGS 9 CALIBRATION 10 BACKLIGHT ON OFF 11 FIRMWARE UPGRADES 12 PDVS2 WINDOWS APPLICATION 13 HARDWARE 14 FREQUENTLY ASKED...

Страница 3: ...uality 4mm banana sockets Calibration Settings test record supplied unique serial number Software function PLAYBACK mode Software function RAMP mode Software function Remote Operation via Windows app...

Страница 4: ...supplied cable Red Blk The battery terminals and the external DC input are reverse polarity protected Use only matched charged state batteries i e don t fit two batteries that are not charged to the...

Страница 5: ...ary encoder to select the digit to be modified which is noted by the underscore below the digit Output Protection The voltage monitor detects when the output has been overloaded or subject to a short...

Страница 6: ...to EEprom when existing playback mode LP ENABLE DISABLE LOOP MODE If loop mode is enable then when playback is running and line 5 finishes it will loop around to the start again automatically With loo...

Страница 7: ...ed to press ENTER 08 no need to press ENTER Changes made are saved to EEprom when existing playback mode LP ENABLE DISABLE LOOP MODE If loop mode is enable then when ramp is running and line 5 finishe...

Страница 8: ...n you connect via USB to a PC Windows the port will auto detect but no data will transfer until comms is enabled FTDI virtual serial port Baud 250k n 8 1 The simple bi directional ascii based serial d...

Страница 9: ...ustable output 4 dp s effective 38 146uV steps Note In this mode the 5th dp is presented and can be controlled but will not necessarily render a change to the voltage output as the resolution is 38 14...

Страница 10: ...r full The charging circuit is self contained but as an added extra the software can shutdown charging if the battery is approaching near full capacity This is done by monitoring the charge current an...

Страница 11: ...c Battery Ext power supply Vdc Span counts Calibration of the Battery external DC supply for the main screen Charge mA Charge current Span counts Calibration of the battery charging current monitor Us...

Страница 12: ...lighting will illuminate for 5 secs Press the rotary encoder switch at any time to illuminate the backlighting On power up the unit defaults to backlighting ON The backlighting intensity dynamically r...

Страница 13: ...that accompanies the HEX file for information and any additional instructions Remove the 4 screws on the back of the unit then locate the PWR BYPASS header and link it out with fresh batteries fitted...

Страница 14: ...ve loaded correctly then usually a COM port other than COM1 will be listed This is the virtual serial port Press CONNECT and the data will appear The Windows app basically mimics the LCD and operation...

Страница 15: ...e Schurter UMZ 250 series FUSE 2 1A time delay fuse Schurter UMZ 250 series J1 3 3Vdc supply to ICSP header Default open ICSP In Circuit Serial Programming header used for uploading new firmware JP1 P...

Страница 16: ...nt drops to 0mA To fix this remove the batteries from the PDVS2 and charge them separately in a standalone charger This will match them again and you can return them to the PDVS2 If this problem persi...

Страница 17: ...product may directly threaten life or injury The user of Ian Johnston Engineering Ltd products in life support aircraft applications or other such critical activities assumes all risks of such use an...

Страница 18: ...pan 10vMode Zero 10vMode Span FUNCTION COUNTS Out Vdc Batt Vdc Charge mA FUNCTION SETTING Batt Low Ind Batt Low Shutdown Batt Chg Enable Batt Chg O L mA Batt Chg Full mA B Light Enable boot FUNCTION U...

Отзывы: