![IAI SEL Скачать руководство пользователя страница 167](http://html1.mh-extra.com/html/iai/sel/sel_instruction-manual_604057167.webp)
10. Position Edit
149
①
Setting of user-specified output port parameters
For the operation method for parameter setting, refer to “14. Parameter Edit.”
The first port No. and the number of ports are set with the following parameters:
▪
Number of ports
I/O parameter No. 74 “Qnt Prt Usr Out” (Number of output ports used by TP user [hand,
etc.])
▪
First port No.
I/O parameter No. 75 “Top No. Use Out” (First output port No. by TP user [hand etc.])
(Setting example) When the first port No. is set to 308 and the number of ports is set to 8:
“Usr1” (F1 key)········ Output port 308
“Usr2” (F2 key)········ Output port 309
“Usr3” (F3 key)········ Output port 310
“Usr4” (F4 key)········ Output port 311
“Usr5” (F1 key)········ Output port 312
“Usr6” (F2 key)········ Output port 313
“Usr7” (F3 key)········ Output port 314
“Usr8” (F4 key)········ Output port 315