![IAI ROBO Cylinder RCS4- SA4C Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/iai/robo-cylinder-rcs4-sa4c/robo-cylinder-rcs4-sa4c_instruction-manual_604042049.webp)
1.2 Specifications
1-30
1. Specifications
3) Read a reference for duty with the figured out “Load Factor” and “Acceleration /
Deceleration Time Ratio”.
e.g.) The reference for duty when the load factor LF is 80% and the acceleration / deceleration time
ratio t
od
is 80% should be approximately 75%.
0
20
40
60
80
100
0
20
40
60
80
100
加減速度時間比率
t
o
d
〔
%
〕
デュ
ー
ティ
ー
の
目安〔
%
〕
LF
= 60%
LF = 50%
未満
約
75%
LF
LF
LF
LF
= 70%
= 80%
= 90%
= 100%
負
荷率〔
%
〕
Reference fo
r Du
ty [%]
Acceleration / Deceleration Time Ratio t
od
[%]
LF
= Below 50%
Load Factor
[%]
Approximately 75%
Содержание ROBO Cylinder RCS4- SA4C
Страница 2: ......
Страница 18: ...Names of the Parts Intro 12 Cleanroom Type Motor Straight Type ...
Страница 56: ...1 37 1 Specifications ...
Страница 78: ...2 21 2 Installation ...
Страница 79: ...Connecting with the Controller 3 1 Connecting with the Controller 3 1 ROBO Cylinder Chapter ...
Страница 140: ...7 3 7 Warranty ...
Страница 141: ...Appendix 8 1 Index 8 1 8 2 Revision history 8 3 ROBO Cylinder Chapter ...
Страница 144: ...8 2 Revision history 8 3 8 Appendix 8 2 Revision history Revision date Revised content 2017 10 First Edition ...
Страница 145: ......