85
9. Maintenance and Inspection
Motor flange
6) Remove the motor.
䈄
Remove the affixing bolts (M3 × 15, 2 pcs./M3 × 18, 2 pcs.) using an Allen wrench of 2.5 mm across
flats.
• Decoupled motor
• Pull out the motor by hand.
• Remove the motor flange.
Remove the affixing bolts (M3 × 8, 4 pcs.) using an
Allen wrench of 2.5 mm across flats.