PCON-CBP
Controller
PIO Input/Output Interface
Types of PIO Patterns (Control Patterns)
Input/output
Input/output
Item
Specifications
Input voltage
24VDC ±10%
Input current
5mA, 1 circuit
ON/OFF voltage
ON voltage: 18VDC min.
OFF voltage: 6VDC max.
Type
Set value of parameter No.25
Mode
Overview
PIO
pattern 0
0
(factory setting)
Positioning mode
(standard type)
•Number of positioning poi
nts: 64 points
•
P
osition number
command: Binary code
•
Zone signal output
*1
: 1 point
•
Position zone signal output
*2
: 1 point
PIO
pattern 1
1
Teaching mode
(teaching type)
•Number of positioning poi
nts: 64 points
•
P
osition number
command: Binary code
•
Position zone signal output
*2
: 1 point
•Jog (inching) ope
ration using PIO signals is
supported
•
Current position da
ta can be w
ritten t
o the position table using PIO si
gnals
PIO
pattern 2
2
256-point mode
(256 positioning
points type)
•Number of positioning poi
nts: 256 points
•
P
osition number
command: Binary code
•
Position zone signal output
*2
: 1 point
PIO
pattern 3
3
512 mode
(512 positioning
points type)
•Number of positioning poi
nts: 512 points
•
P
osition number
command: Binary code
•No
zone signal output
PIO
pattern 4
4
Solenoid valve
mode 1
(7-point type)
•Number of positioning poi
nts: 7 points
•
P
osition number
command: Individual
number si
gnal ON
•
Zone signal output
*1
: 1 point
•
Position zone signal output
*2
: 1 point
PIO
pattern 5
5
Solenoid valve
mode 2
(3-point type)
•Number of positioning poi
nts: 3 points
•
P
osition number
command: Individual
number si
gnal ON
•
Completion signal: A signal equivalent t
o a LS (limit swi
tch) sig
nal can be output
•
Zone signal output
*1
: 1 point
•
Position zone signal output
*2
: 1 point
PIO
pattern 6
6
Force control mode 1
•Number of positioning poi
nts: 32 points
•
P
osition number
command: Binary code
•
Position zone signal output
*2
: 1 point
•
Load c
ell calib
ration command
PIO
pattern 7
7
Force control mode 2
•Number of positioning poi
nts: 5 points
•
P
osition number
command: Individual
number si
gnal ON
•
Position zone signal output
*2
: 1 point
•
Load c
ell calib
ration command
Item
Specifications
Load voltage
24VDC
Maximum load current 50mA, 1 circuit
Leakage current
2mA max./point
P
N
N
P
P24
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
N
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
P24
Load
N
15
Output terminal
24VDC
External
power supply
Internal
circuit
P24
Load
N
Output terminal
24VDC
External
power supply
Internal
circuit
15
P
N
N
P
P24
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
N
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
P24
Load
N
15
Output terminal
24VDC
External
power supply
Internal
circuit
P24
Load
N
Output terminal
24VDC
External
power supply
Internal
circuit
15
P
N
N
P
P24
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
N
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
P24
Load
N
15
Output terminal
24VDC
External
power supply
Internal
circuit
P24
Load
N
Output terminal
24VDC
External
power supply
Internal
circuit
15
P
N
N
P
P24
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
N
5.6k
680
24VDC
Input terminal
External
power supply
Internal
circuit
P24
Load
N
15
Output terminal
24VDC
External
power supply
Internal
circuit
P24
Load
N
Output terminal
24VDC
External
power supply
Internal
circuit
15
This controller has 8 types of control methods.
Please set the PIO pattern that best suits your application in Parameter No.25, "PIO Pattern Selection."
*1 Zone signal output: Please set the desired zone range in Parameter No.1/2 or 23/24. I
t will
remain effective once home return is completed.
*2 Position zone signal output: This command function relates t
o the position numbe
r. Set the desired zone r
ange in the position tabl
e.
This func
tion will only be
c
ome enabled when the
corresponding position is specified. I
t will be disabled
for all other position commands.
21
PCON-CBP