29
Appendix 1
Output Current for When Connecting Multiple Power Supply Units
Table: 2 Rated Output Current and Peak Output Current of Power Source
No. of Connectable Units
Rated Output Current [A]
Peak Output Current [A]
1 unit
8.5
17
2 units
15.3
30.6
3 units
22.95
45.9
4 units
30.6
61.2
5 units
38.25
76.5
(Note)
For the 2nd unit or more, 10% safety factor (loss) is considered.
Output Current of One Unit × Connected Number of Units × 0.9