Table: 1-6 Relation of Actuator and Power Supply Current (Actuator with Integrated Controller)
Actuator Type
Motor Power Capacity
Power Supply Current [A]
(Note 1)
ELECYLINDER
EC-PR4,
EC-GS4,
EC-GD4,
EC-TC4,
EC-TW4
Max.
2.0
Other than Above
Power
Consumption
Setting Valid
Max.
2.2
Power
Consumption
Setting Invalid
Rated
3.5
Max.
4.2
ERC3
High-Output
Setting Invalid
Max.
2.2
High-Output
Setting Valid
Rated
3.5
Max.
4.2
RCP6S
35P,
42P,
56P
High-Output
Setting Invalid
Max.
2.0
High-Output
Setting Valid
Rated
3.5
Max.
4.5
56SP, 60P
Max.
6.0
Note 1 The supply current should include the control supply current.
(Note) “Fieldbus Type” increases the current by 0.3A.
For how to calculate the current amperage for RCP6S Gateway System, refer to “1.3 Calculation
for Connectable Number of Axes and Calculation for Current Amperage” in RCP6S Fieldbus