Chapter 8 Parameter
POWER CON
PCON-CB/LC
205
[79] GS velocity loop proportional gain (Parameter No.145)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
145 GS velocity loop proportional gain GSPC
–
1 to 30000
750
When the gain scheduling upper multiplying rate (Parameter No.144) is set to 101 or more, this
parameter setting becomes effective for Velocity Loop Proportional Gain.
[Refer to the 8.2 [24] Velocity loop proportional gain for the details]
[Reference Item] 8.2 [89] Selecting the Use of velocity loop proportional gain and velocity loop
integrated gain.
[80] GS velocity loop integral gain (Parameter No.146)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
146 GS velocity loop integral gain
GSIC
–
1 to 500000
4500
When the gain scheduling upper multiplying rate (Parameter No.144) is set to 101 or more, this
parameter setting becomes effective for Velocity Loop Integrated Gain.
[Refer to the 8.2 [25] Velocity loop integral gain for the details]
[Reference Item] 8.2 [89] Selecting the Use of velocity loop proportional gain and velocity loop
integrated gain.
[81] Total movement count threshold (Parameter No.147)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
147 Total movement count threshold
TMCT
Times
0 to 999999999
0(Disabling)
A light error alarm is generated when the total movement count exceeds the value set to this
parameter.
The judgment would not be made if the value is set to 0.
[82] Total operated distance threshold (Parameter No.148)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
148 Total operated distance threshold
ODOT
m
0 to 999999999
0(Disabling)
A light error alarm is generated when the total operation distance exceeds the value set to this
parameter.
The judgment would not be made if the value is set to 0.
[83] Zone output changeover (Parameter No.149)
No.
Name
Symbol
Unit
Input Range
Default factory
setting
149 Zone output changeover
FPIO –
0: Not to change
1: To change
0
When there is PZONE signal to the current PIO pattern or the Fieldbus Operation Mode and no
ZONE1 or ZONE2 signal, it is available to change the PZONE signal to either ZONE1 or
ZONE2 signal.
Caution:
x
ZONE1 signal is assigned prior to ZONE2 signal.
x
It would not function in the pulse train mode.
x
In the case there is no PZONE signal in PIO patterns, or both ZONE1 and
ZONE2 signals exist, the setting would be invalid.
Содержание PCON-CB series
Страница 2: ......
Страница 4: ...POWER CON PCON CB LC ...
Страница 14: ...POWER CON PCON CB LC ...
Страница 32: ...POWER CON PCON CB LC 18 ...
Страница 84: ...Chapter 2 Wiring POWER CON PCON CB LC 70 ...
Страница 173: ...Chapter 4 Field Network POWER CON PCON CB LC 159 4 CompoNet Type 5 EtherNet IP Type 6 MECHATROLINK Ⅰ Ⅱ Type ...
Страница 174: ...Chapter 4 Field Network POWER CON PCON CB LC 160 7 EtherCAT Type 8 PROFINET IO Type ...
Страница 190: ...Chapter 7 Absolute Reset and Absolute Battery POWER CON PCON CB LC 176 ...
Страница 226: ...Chapter 8 Parameter POWER CON PCON CB LC 212 ...
Страница 262: ...Chapter 10 Appendix POWER CON PCON CB LC 248 4 TP Adapter and Accessories 1 TP adapter external dimensions RCB LB TGS ...
Страница 330: ...Chapter 10 Appendix POWER CON PCON CB LC 316 ...
Страница 334: ......
Страница 335: ......