Emergency Stop Circuit

Control/Driving Power Supply
(24V DC
…Please prepare separately)

AK -04

Way to lay out wirings differs 
depending on the specifications of 
the host when pulse train control 
mode (for PLN and PLP types only).
[Refer to Pulse Train Mode 
Operation described later.]

Controller Status 
Display LED

Teaching Pendant
Touch Panel Teaching
(to be purchased separately)

4.  Heat Radiation and Installation 

Design and Build the system considering the size of the controller box, location of the controller and 
cooling factors to keep the ambient temperature around the controller below 40

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Connection Diagram 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

  Connection to RCP2 (High-Thrust), RCA and RCL Series 

 

PCON

ACON

 

 

  Connection to RCP3, RCP4, RCP5, RCP6 and RCA2 Series 

 

Connection
Cable

(Note1)

PCON

ACON

 

 

  Connection to RCD Series 

 

DCON

Connection
Cable

(Note1)

 

 

Note 1  Applicable Connection Cable Model Codes     

□□□

 : Cable Length    Example) 030 = 3m 

 
 
 

Model Name 

Cable 

Reference 

RCP2 CB-PSEP-MPA

□□□

 

Robot cable from 0.5 to 20m 

RCP3 

CB-APSEP-MPA

□□□

 

Robot cable from 0.5 to 20m 

CB-APSEP-MPA

□□□

-LC  Standard cable from 0.5 to 20m 

RCP4

 

(Other than GR* Type) 

RCD (Applicable Controller 

Symbol : D3) 

CB-CA-MPA

□□□

-RB 

Robot cable from 0.5 to 20m (Note 1) 

CB-CA-MPA

□□□

 

Standard cable from 0.5 to 20m (Note 1) 

RCP4

 

(GR Type), RCP5,   

RCP6 (Including Pulse Press) 

RCD (Applicable Controller 

Symbol : D5) 

CB-CAN-MPA

□□□

 

Standard cable from 0.5 to 20m (Note 1) 

CB-CAN-MPA

□□□

-RB 

Robot cable from 0.5 to 20m (Note 1) 

High-Thrust 

RCP2 

CB-CFA-MPA

□□□

 

Standard cable for CFA type from 0.5 to 20m 

CB-CFA-MPA

□□□

-RB 

Robot cable for CFA type from 0.5 to 20m 

RCP4 

CB-CFA2-MPA

□□□

 

Standard cable for CFA type from 0.5 to 20m 

CB-CFA2-MPA

□□□

-RB 

Robot cable for CFA type from 0.5 to 20m 

RCP5

RCP6 

CB-CFA3-MPA

□□□

 

Standard cable for CFA type from 0.5 to 20m 

CB-CFA3-MPA

□□□

-RB 

Robot cable for CFA type from 0.5 to 20m 

RCA, RCL (Incremental Type) 

CB-ASEP-MPA

□□□

 

CB-ASEP2-MPA

□□□

 

Robot cable from 0.5 to 20m 

RCA (Serial Absolute Type) 

CB-APSEP-MPA

□□□

 

Robot cable from 0.5 to 20m 

RCA2 

Note 1  The length is up to 10m for RCD 

 

 

Power Supply and Emergency Stop Circuit 

This shows the circuit example when the emergency stop switch in the teaching pendant is enabled on the 
emergency stop circuit to be built up by the client. 
In the example below, uses PCON-CA. It is the same in case of except for PCON-CA. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
Note 1 : 

The safety categories complied type (CGB Type, etc.) is not equipped with the relay to have the controller 

automatically identify that a teaching tool was plugged in and switch the wiring layout. Those other than the safety 
categories complied type do the automatic identification and have S1 and S2 short-circuited. 

Note 2 : 

When the motor driving source is cut off externally for a compliance with the safety category, connect a contact 

such as a contactor to the wires between MPI and MPO. Also, the ratings for the emergency stop signal that turns 
ON/OFF at the contact CR1 are 24V DC and 10mA or less. 

Note 3 : 

For CR1, select the one with coil current 0.1A or less. 

 

Caution 

If supplying power with using a 24V DC, having it turned ON/OFF, keep the 0V connected and have the 
+24V supplied/cut (cut one side only). 

 

 
[Reference] Example for operating an actuator by using the standard type (CA or CB Type) with optimum   

wiring layout 

(Note)

 

In this example, the emergency stop switch on the teaching pendant would not work. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

I/O Signal 

Explanation of I/O Signal Functions 

Category Abbreviated Code 

Signal Name 

Contents of Functions 

Input 

CSTR PTP 

Strobe 

(Start Signal) Starts moving toward the position set in Command Position No. 

PC1 to PC256  Command Position No. 

To input position No. desired to move (binary input). 

BKRL 

Brake Compulsory Release  To release the brake compulsorily. 

RMOD 

Operation Mode 

Changeover 

Operation Mode can be changed over when MODE Switch on the controller 

is on AUTO. (The setting is AUTO when signal is OFF, and MANU when ON.) 

*STP Pause 

When this signal is turned OFF while in move, the actuator decelerates 

and then stops. The remaining movement is in a hold while the actuator is 

stopped and will resume when the signal turns back ON. 

RES Reset 

Turn the signal ON to reset the alarm. Also, when it is turned ON in the 

pause mode (*STP is turned OFF), the remaining movement amount can 

be cancelled. 

SON 

Servo ON 

The servo remains ON while this signal is ON, or OFF while this signal is OFF. 

HOME 

Home Return 

The controller will perform home return operation when this signal is turned ON. 

MODE Teaching 

Mode 

The operating mode will change to the teaching mode when this signal is 

turned ON. The mode will not be switched over unless CSTR, JOG

 and 

JOG

 are all OFF and the actuator operation is stopped. 

JISL Jog/Inching 

Changeover 

Jog Operation can be performed with JOG

 and JOG

 while this signal is 

OFF. Inching Operation is performed with JOG

 and JOG

 when it is ON. 

JOG

   

JOG

 

Jog 

Jog Operation is performed to positive direction by detecting ON edge of 

JOG

 signal and to negative direction by JOG

 signal while JISL signal is 

OFF. The actuator will decelerate and stop if OFF edge is detected while in 

each Jog Operation. 

Inching Operation is performed while JISL signal is ON. 

PWRT Current 

Position 

Writing 

Write the current position to the indicated position if indicating the written position 

and turn this signal ON for more than 26ms during the Teaching Mode. 

CLBR

(Note1)

  Loadcell Calibration 

Command 

Turn this signal on for 20ms or more and calibration of the loadcell should 

be performed. 

ST0 to ST6  Start Signal 

The actuator moves to the commanded position with this signal ON during 

the electromagnetic valve mode.

 

CSTP Compulsory 

Stop 

Turning it continuously input for more than 16ms compulsorily stops the 

actuator. 

TL Torque 

Limit 

Select  Puts torque limitation to the motor with the signal on and the value set to 

the parameter. 

DCLR 

Deviation Counter Clear  This is the signal to clear up the differential counter. 

RSTR 

Datum Position 

Movement Command 

Applies torque limit to the motor with the signal ON and the value set to the 

parameter No.167 

Output 

PEND/INP Position 

Completion 

Turns ON in the positioning band range after actuator operation. The INP 

signal will turn OFF if the position deviation exceeds the in-position range. 

PEND and INP can be switched over by the parameter. 

PM1 to PM256  Completion Position No.  The position No. reached after the positioning completion, is output (binary output). 

HEND 

Home Return Completion  Turns ON when home-return operation is complete. It will be kept ON 

unless the home position is lost. 

ZONE1 

ZONE2 

Zone 

Turns ON if the current actuator position is within the range set to the 

parameter. 

PZONE Position 

Zone 

Turns ON when the current actuator position gets into the range set to the 

position data during the move towards the position. Even though it can be 

used together with ZONE1, PZONE will become only available for 

operation by the set position number. 

RMDS 

Operation Mode Output 

Outputs the operation mode status. It turns ON when the controller is ON 

Manual Mode. 

*ALM Alarm 

Turns ON when controller in normal condition, and OFF when alarm is 

generated. 

ALM1 to 8

 

Alarm Code

 

The detail of the alarm is output with binary code when an alarm more than 

the operation cancel level is issued. 

MOVE 

While in Operation 

Turns ON while the actuator is moving (including home return and 

pressing operations). 

SV Servo 

ON 

Turns ON when the servo is ON. 

*EMGS Emergency 

Stop 

Output 

Turns ON when the controller emergency stop is cancelled, and OFF 

during the emergency stop (regardless of alarms). 

MODES 

Teaching Mode Output 

Turns ON when it turns to the Teaching Mode by MODE signal input. It is 

OFF in the normal mode. 

WEND Writing 

Complete 

It is OFF during the teaching mode and turns ON when the writing by 

PWRT Signal is complete. It turns OFF when PWRT Signal turns OFF. 

PE0 to PE6  Current Position Number  Turns ON when moving to the target position is complete in 

Electromagnetic Valve Mode. 

LS0 to LS2  Limit Switch Output 

Turns ON when the current actuator position is within the range of 

positioning band (

) of the target position. It is output even before the 

movement command and the servo is OFF if the home-return operation is 

completed. 

CEND

(Note1)

  Loadcell Calibration 

Complete 

It turns on once the loadcell calibration is complete. Turn CLBR Signal off 

and this signal also turns off. 

*ALML Light 

Error 

Output 

Outputs when a message level alarm is generated. 

(Parameter setting necessary) 

LOAD

(Note2)

  Load Output Judgment 

Signal 

Output is made when the current exceeded the value set in “Threshold” for 
certain time

 (Note)

 within the range of “Zone+” and “Zone-“ in the position 

data during the pressing operation.

 

(Note) Setting to be established in Parameter No. 50 
It is used for judgments such as to determine if press-fitting process is 
completed normally.

 

TRQS

(Note2)

 Torque 

Level 

Output 

Turns ON when the motor current has exceeded the value set in 

“Threshold” in the position table in such cases as the slider (or rod) hitting 

an obstacle while in pressing operation, and turns OFF when current goes 

below the value 

*BALM 

(ACON only) 

Absolute battery voltage 

drop alarm 

It turns on when the battery is in the normal voltage range for the serial 

absolute type actuator. 

It is on all the time for the incremental type actuator. 

It can be set to turn off when a message level alarm is generated by the 

setting in Parameter No. 151. 

TLR Torque 

Limit 

Restricted

 

Turns ON when torque reaches the limit while in torque restriction.

 

REND 

Datum Position 

Movement Command 

Turns ON when movement to the datum position set in Parameter No.167 

is finished. 

Signal with “*” expresses the signal of active low. It is ON when the power is applied to the controller, and turns OFF when the 
signal is output. 
(Note 1)  The PIO patterns assigned to this signal are dedicated for PCON-CBP/CGBP types. It cannot be used in 

PCON-CB/CGB/CFB/CGFB. 

(Note 2)  It is a signal dedicated for the pulse pressing and the high-thrust actuators (CFA/CFB types).Use this as a reference 

output for other actuators. 

MIN.
30mm

MIN.
30mm

MIN.
30mm

MIN.
30mm

MIN. 100mm

MIN. 50mm

MIN. 100mm

Ensure enough space 
for wiring.

 

Absolute 
Battery Unit 
[Refer to 
instruction 
manual for each 
model] 

S1

S2

MPI

MPO

24V

0V

24V

0V

EMG-

BKLS

Power Supply 

Connector

Emergency-stop 
Switch on the 
Teaching Pendant 

Control 
Power 
Supply

SIO Connector

Wiring Condected
at Delivery

24V DC
Power Supply

Motor Power Supply

Emergency Stop Control Circuit

Brake Release Power Supply

(Note) Supply 24V when connecting actuator
           equipped with brake and release brake
           compulsorily

Emergency
-stop Switch 

24V 

0V 

0V 

Emergency 
Stop Reset 
Switch

Emergency 
Stop Switch

CR1

S1

S2

MPI

MPO

24V

EMG-

BKLS

CR1

 

(Note 3)

Brake Forced 
Release Switch

Power Supply 

Connector

PCON-CA

Emergency-stop 
Switch on the 
Teaching Pendant 

Control 
Power 
Supply

SIO Connector

(Note 1)

Motor Power Supply

CR1

 

(Note 2)

Emergency Stop Control Circuit

Brake Release Power Supply

(Note) Supply 24V when connecting actuator
           equipped with brake and release brake
           compulsorily

Отзывы: