<Encoder Resolution>    See below for the resolution of encoders mounted on the

 

connectable actuators. 

Actuator Type 

Encoder Resolution 

RCP2 to 5 

All Types 

    800 pulse/rev 

Pulse Motor 

RCP6 

All Types 

  8192 pulse/rev 

Incremental Encoder 

    800 pulse/rev 

RCA 

Battery-less Absolute Encoder 

16383 pulse/rev 

RCA2-□□□N(A) 

1048 pulse/rev 

RCA2 

Except for RCA2-□□□N(A) 

  800 pulse/rev 

RA1L 

 SA1L 

 SA4L 

 SM4L 

    715 pulse/30.03 mm 

RA2L 

 SA2L 

 SA5L 

 SM5L 

  855 pulse/35.91 mm 

Servo Motor 

RCL 

RA3L 

 SA3L 

 SA6L 

 SM6L 

1145 pulse/48.09 mm 

RA1D 

 GRSN 

400 pulse/rev 

Brushless DC 
Motor 

RCD 

RA1DA 

 GRSNA 

480 pulse/rev 

● Specifications of DeviceNet Interface 

Item 

Specification 

Communication Protocol 

DeviceNet 2.0, Group 2 Dedicated Server, Network-Powered Insulation Node 

Baud Rate, Communication System 

Automatically follows the master, Master-Slave System (Polling) 

Number of Occupied Channels, 
Number of Occupied Node 

MAX. 72CH (Input, Output), 1 node 

Baud Rate 

Max. Network 

Length 

Total Branch Line 

Length 

Max. Branch Line 

Length 

500kbps 

100m 

39m 

250kbps 

250m 

78m 

Communication Cable Length 

(Note 1)

 

125kbps 

500m 

156m 

6m 

Communications Cable 

Use the dedicated cable. 

Connector 

(Note 2)

 

MSTB2.5/5-GF-5.08 AU (Manufactured by PHOENIX CONTACT or equivalent) 

Communication Power Supply, 
Consumption Current 

24V DC (Supplied from DeviceNet), 60mA 

Note 1  For T branch communication, refer to the Instruction Manuals for the master unit and programmable controller (PLC) 

to be mounted.

 

Note 2  The cable-side connector is a standard accessory. [Refer to Product Check 1.Parts] 

● Specifications of CC-Link Interface 

Item 

Specification 

Communication Protocol 

CC-Link ver 1.10 or ver 2.00 

Station Type 

Remote Device Station (MAX. four stations occupied) 

Baud Rate, Communication System 

10M/5M/2.5M/625k/156kbps, Broadcast Polling System 

Number of Connectable Stations 

MAX. 63 stations 

Baud Rate (bps) 

10M 

5M 

2.5M 

625k 

156k 

Communication Cable Length 

(Note 1)

 

Total Cable Length (m) 

100 

160 

400 

900 

1200 

Communications Cable 

Use the dedicated cable. 

Connector 

(Note 2)

 

MSTB2.5/5-GF-5.08 AU (Manufactured by PHOENIX CONTACT or equivalent) 

Note 1  For T branch communication, refer to the Instruction Manuals for the master unit and programmable PLC to be mounted.

 

Note 2  The cable-side connector is a standard accessory. [Refer to Product Check 1.Parts] 

● Specifications of PROFIBUS-DP Interface 

Item 

Specification 

Communication Protocol 

PROFIBUS-DP 

Baud Rate, Communication System 

Automatically follows the master, Hybrid System (Master-Slave System or Token 
Passing System) 

Occupied Domain 

MAX. 144 byte (Input, Output) 

Number of Connectable Stations 

MAX. 32 stations/segments    available up to 126 stations with repeater 

MAX. Total Network 

Baud Rate 

Cable Type 

100m 

3,000/6,000/12,000kbps 

200m 

1,500kbps 

400m 

500kbps 

1000m 

187.5kbps 

Communication Cable Length 

(Note 2)

 

1200m 

9.6/19.2/93.75kbps 

Type A Cable 

Communications Cable 

STP cable AWG18 

Connector 

(Note 1)

 

9-pin female D-sub Connector 

Transmission Path Format 

Bus/Tree/Star 

Note 1  Please prepare a 9-pin male D-sub connector for the cable-end connector.

 

● Specifications of CompoNet Interface 

Item 

Specification 

Communication System 

CompoNet dedicated protocol 

Communication Type, Baud Rate 

Remote I/O communication, Automatically follows the master 

Communication Cable Length 

Follows CompoNet specifications 

Slave Type 

Word-Mixed Slave 

Available Node Addresses for Setting  0 to 63 (Setting conducted on controller parameter) 

Communications Cable   
(To be prepared by User) 

Round Cable (JIS C3306, VCTF2-core) 
Flat cable I (with no sheathed) 
Flat cable II (sheathed) 

Connector (Controller Side) 

XW7D-PB4-R (Manufactured by OMRON or equivalent) 

● Specifications of EtherNet/IP Interface 

Item 

Specification 

Communication Protocol 

IEC61158 (IEEE802.3) 

Baud Rate 

10BASE-T/100BASE-T (Autonegotiation setting is recommended) 

Communication Cable Length 

Follows EtherNet/IP specifications   
(Distance between hub and each node: 100m max.) 

Number of Connection 

Master Unit 

Available Node Addresses for Setting  0.0.0.0 to 255.255.255.255 
Communications Cable   
(To be prepared by User) 

Category 5 or more 
(Double shielded cable braided with aluminum foil recommended) 

Connector 

RJ45 Connector × 1pc 

 

● Specifications of EtherCAT Interface 

Item 

Specification 

Communication Protocol 

IEC61158 type 12 

Physical Layer 

100Base-TX (IEEE802.3) 

Baud Rate 

Automatically follows the master 

Communication Cable Length 

Follows EtherCAT® specifications (Distance between each node: 100m max.) 

Slave Type 

I/O slave 

Available Node Addresses for Setting 

0 to 127 

Communications Cable   
(To be prepared by User) 

Category 5 or more 
(Double shielded cable braided with aluminum foil recommended) 

Connector 

RJ45 Connector × 2pcs (Input × 1, Output × 1) 

Connect 

Daisy chain only 

● Specifications of PROFINET IO Interface 

Item 

Specification 

Communication Protocol 

IEC61158 (IEEE802.3), IEC61784 

Baud Rate 

100Mbps 

Communication Cable Length 

Distance between each segment: 100m Max. 

Number of Connection 

Master Unit 

Available Node Addresses for Setting 

0.0.0.0 to 255.255.255.255 

Communications Cable   
(To be prepared by User) 

Category 5 or more 
(Double shielded cable braided with aluminum foil recommended) 

Connector 

RJ45 Connector × 1pc 

GSDML File Version 

Ver 2.3 

● Specifications of CC-Link IE Field Interface 

Item 

Specification 

Communication Protocol, Baud Rate 

Conforms to IEEE802.3ab (1000BASE-T), 1Gbps 

Communication System 

Token Passing System 

Communication Cable Length 

Distance between each segment: 100m Max. 

Max. Number of Connected Units,   
Max. Networks 

254units (Total of master and slave stations), 239networks 

Communications Cable   
(To be prepared by User) 

Category 5e or more   
(Double shielded cable braided with aluminum foil recommended) 

Connector 

RJ45 Connector × 2pcs 

Cyclic Communication 

RX (Slave → Master): 16384bits, RY (Master → Slave): 16384bits 
RWr (Slave → Master): 8192words, RWw (Master → Slave): 8192words 

● Refer to SSCNET

/H interface specifications, SSCNET

/H Applicable for Controller Instruction Manual (ME0352). 

● Refer to MECHATROLINK-

  interface specifications, 

MECHATROLINK-

  Applicable for Controller 

Instruction Manual (ME0317). 

● Refer to EtherCAT Motion interface specifications, EtherCAT Motion Applicable for Controller Instruction 

Manual (ME0367). 

 

External Dimensions

 

Controller Main Body 

123

115

95

7.5

59 from DIN rail center

10.5

10.5

4

111

108

φ

5

5

5

(4)

φ

5

 

Absolute Battery Box

 

111

108

φ

5

φ

5

5

5

(4)

123

115

59 from DIN rail center

10.5

4

98

 

 

Installation Environment 

This product is capable for use in the environment of pollution degree 2

*1

 or equivalent. 

* 1  Pollution Degree 2 : Environment that may cause non-conductive pollution or transient conductive 

pollution by frost (IEC60664-1). 

1.  Installation Environment 

Do not use this product in the following environment. 

 Location where the surrounding air temperature 

exceeds the range of 0 to 40

 Location where condensation occurs due to abrupt 

temperature changes 

 Location where relative humidity exceeds 85%RH 

 Location exposed to corrosive gases or combustible 

gases 

 Location exposed to significant amount of dust, salt or 

iron powder

 

 Location subject to direct vibration or impact 

 Location exposed to direct sunlight 

 Location where the product may come in contact with 

water, oil or chemical droplets 

 Environment that blocks the air vent   

[Refer to Installation and Noise Elimination] 

When using the product in any of the locations specified below, provide a sufficient shield. 

  Location subject to electrostatic noise 

  Location where high electrical or magnetic field is present 

  Location with the mains or power lines passing nearby 

2.  Storage and Preservation Environment 

  Storage and preservation environment follows the installation environment. Especially in a long-term storage, 

consider to avoid condensation of surrounding air. 
Unless specially specified, moisture absorbency protection is not included in the package when the machine is 
delivered. In the case that the machine is to be stored in an environment where dew condensation is anticipated, take 
the condensation preventive measures from outside of the entire package, or directly after opening the package.

 

 

Installation and Noise Elimination 

 

1. Noise Elimination Grounding (Frame Ground)

 

 
 
 
 
 
 
 
 
 
 
 
 
 

2.  Precautions regarding wiring method 

1)  Wire is to be twisted for the 24V DC power supply. 
2)  Separate the signal and encoder lines from the power supply and power 

lines. 

3.  Noise Sources and Elimination 

Carry out noise elimination measures for electrical devices on the same 
power path and in the same equipment. 
The following are examples of measures to eliminate noise sources. 
1)  AC solenoid valves, magnet switches and relays 

[Measure]  Install a Surge absorber parallel with the coil. 

2)  DC solenoid valves, magnet switches and relays 

[Measure]  Mount the windings and diodes in parallel. Select a diode 

built-in type for the DC relay.

 

4.  Cooling Factors and Installation 

Design and Build the system considering the size of the controller box, location of the controller and cooling factors to keep 
the surrounding temperature around the controller below 40

C. 

Pay a special attention to the battery unit since the performance of it would drop both in the low and high temperatures. 
Keep it in an environment in the room temperature as much as possible. (Approximately 20

C is the recommended 

temperature.)

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

For the attachment of the unit, use the fixture holes on the four corners or 
attach on the DIN rail. (Attachment should be the same for the absolute 
battery box.) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

Earth Terminal 
Grounding resistance at 100

 or less

 (

Class D grounding

Copper wire: Connect a ground 
wire with a diameter of 1.6 mm 
(2mm

2

: AWG 14) or larger.

 

Connect the ground line to the FG 
terminal block on the controller 
unit. 
Put a tool such as a screwdriver 
into the square slot and connect 
the line. 

Do not share the ground wire with or connect 
to other equipment. Ground each controller.

Controller

Other 

equipment

Controller

Other 

equipment

Other 

equipment

Surge absorber

Relay 
coil

Relay coil

R

C

+24V

0V

+24V

0V

+

-

20mm or more

50mm 
or more

Ensure 
enough space 
for wiring.

50mm or more

Air outlet

Air outlet

(Heat 

(Heat 

Radiation)

Radiation)

Air outlet

(Heat 

Radiation)

Air inlet

Air inlet

Air inlet

20mm 
or more

20mm 
or more

20mm 
or more

20mm 
or more

Ceiling 

Rear View

DIN rail

Lever for attachment to DIN rail

φ

5 fixture hole

Отзывы: