— 52 —
GO-2400M-USB / GO-2400C-USB
Item
Setting range
Default value
Description
ALC Area Enable All
True, False
True
Set whether to enable ALC for all areas.
ASC Min.
100 to 6209
100
Set the minimum value for the ASC range.
ASC Max.
101 to 6210
6210
Set the maximum value for the ASC
range.
AGC Min.
100 to 1599
100
Set the minimum value for the AGC
range.
AGC Max.
101 to 1600
1600
Set the maximum value for the AGC
range.
AGC/ASC Control Speed
1 to 8
4
Set the reaction speed for AGC/ASC.
These settings are also used for auto
exposure control.
ALC Status
—
Idle
Display the status of the ALC.
n) JAI Custom Control Blemish
Configure settings for JAI white blemish
correction.
Blemish Enable
True, False
True
Set whether to enable white blemish
correction.
Blemish Detect
—
—
Detect white blemishes.
Blemish Detect Threshold
0 to 100
10
Set the white blemish detection threshold.
Blemish Detect Position Index
0 to 511
0
Select the index table for the white
blemish detection position.
Blemish Detect Position X
–1 to 1935
–1
Set the horizontal position.
Blemish Detect Position Y
–1 to 1215
–1
Set the vertical position.
Blemish Compensation
Number
—
0
Display the number of correction
blemishes.
o) JAI Custom Control Shading
Configure shading correction settings.
Shading Correction Mode
GO-2400M-USB:
Flat Shading (fixed)
GO-2400C-USB:
Flat Shading, Color
Shading
Flat Shading
Select the shading correction mode.
Shading Mode
Off, User 1, User 2, User 3
Off
Select whether to use shading correction.
When using the function, select the user
area to which to save the shading
correction value.
Perform Shading Calibration
—
—
Execute shading correction. After
execution, the shading correction value is
automatically saved to the selected user
area.
Shading Detect Result
—
—
Display the shading detection results.
p) JAI Custom Control Sensor
MultiROI
Configure settings for JAI sensor multi
ROI.
Sensor Multi Roi Enable
True, False
False
Enable/disable sensor multi ROI.
Sensor Multi Roi Index
Index 1 to 4
Index 1
Select the sensor multi ROI index table.
Sensor Multi Roi Width
16 to 1936/16 steps
256
Set the width. When binning is enabled
on the GO-2400M-USB, the maximum
value will change.
Sensor Multi Roi Height
2 to 1216/2 steps
160
Set the height. When binning is enabled
on the GO-2400M-USB, the maximum
value will change.
Sensor Multi Roi Offset X
0 to 1680/16 steps
❖
maximum value
= 1936 - width value
0
Set the horizontal position. When binning
is enabled on the GO-2400M-USB, the
maximum value will change.
Sensor Multi Roi Offset Y
0 to 1056/2 step
❖
maximum value
= 1216 - height value
0
Set the vertical position. When binning is
enabled on the GO-2400M-USB, the
maximum value will change.
Horizontal Enable
True, False
False
Enable/disable horizontal offset.
Vertical Enable
True, False
False
Enable/disable vertical offset.