3. O
peration of ELECYLINDER
52
ME0375-4A
(Reference) Acceleration is explained. The same concept applies to deceleration.
1G = 9800mm/s
2
: Acceleration at which the actuator can increase its speed up to
9800mm/s per second.
0.3G :
Acceleration at which the actuator can increase its speed up to
2940mm/s (9800mm/s × 0.3) per second.
8) Transfer log
Once the data of the velocity and acceleration/deceleration for the way forth and the way back
is transferred by pressing [Transfer] button, the old setting parameters will be shown in the
previous setting area and the new parameters in the current setting area, and the cycle time
calculated from these parameters will be displayed.
Caution: If the actuator or work part receives impact or generates vibration, lower the
acceleration/deceleration. If the system is used continuously with the actuator or
work part receiving impact or generating vibration, the life of the actuator may be
significantly reduced.
Velocity
Time
9800mm/s
1s
1G
2940mm/s
0.3G
8)