![IAI ELECYLINDER EC-RTC9 Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/iai/elecylinder-ec-rtc9/elecylinder-ec-rtc9_instruction-manual_3184366108.webp)
4.3 Stop position / operating conditions (AVD) setting/adjustment
4-6
4. Operation
Stop position setting/adjustment (forward end / backward end)
Setting item
Unit
Explanation
Backward end,
forward end
degree Enter as the distance from the home position.
Entries can be made in increments of 0.01 degrees.
Touch the position you want to configure/adjust.
Ten Key window will open.
After setting the numerical value, touch the [ENT] key.
Then touch the [Transfer] key.
A value will be written to the controller and the [B. End]
button and [F. End] button will turn green.
Press the [F. End] or [B. End] buttons to operate.
Check the results of the new setting/adjustment.
Note that pressing the button while operating will cause the ELECYLINDER to slow to a
stop in place.
Action
2
1
Action
3
Содержание ELECYLINDER EC-RTC9
Страница 2: ......
Страница 26: ...1 5 Accessories 1 35 Power I O cable 1 35 Power I O connector 1 36...
Страница 64: ......
Страница 78: ...2 14 2 Installation...
Страница 80: ......
Страница 100: ...3 20 3 Wiring...
Страница 124: ...4 22 4 Operation...
Страница 126: ......
Страница 132: ...5 6 5 Preventive Predictive Maintenance...
Страница 134: ......
Страница 148: ...6 14 6 Parameters...
Страница 150: ......
Страница 168: ...7 18 7 Troubleshooting...
Страница 170: ......
Страница 207: ...External Dimensions 9 1 Rotary external dimensions 9 1 EC RTC9 9 1 EC RTC12 9 2 ELECYLINDER Chapter...
Страница 208: ......
Страница 211: ...Life 10 1 Concept of life for Rotary 10 1 10 2 Concept of life for controller 10 1 ELECYLINDER Chapter10...
Страница 212: ......
Страница 214: ...10 2 10 Life...
Страница 216: ......
Страница 219: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12...
Страница 220: ......
Страница 225: ......