3. XSEL-R(A)/S(A)/R(A)X/S(A)X/R(A)XD/S(A)XD
34
2.6 I/O Port Numbers for X-SEL
The table below lists the standard I/O port numbers for X-SEL controllers.
On X-SEL controllers, port numbers and function assignments can be changed using I/O parameters. (For
details, refer to the “Operation Manual for X-SEL Controller.”)
Port No.
Function
Port No.
Function
000
Program start
300
Alarm output
001
General-purpose input
301
Ready output
002
General-purpose input
302
Emergency stop output
003
General-purpose input
303
General-purpose output
004
General-purpose input
304
General-purpose output
005
General-purpose input
305
General-purpose output
006
General-purpose input
306
General-purpose output
007
Program specification (PRG No. 1)
307
General-purpose output
008
Program specification (PRG No. 2)
308
General-purpose output
009
Program specification (PRG No. 4)
309
General-purpose output
010
Program specification (PRG No. 8)
310
General-purpose output
011
Program specification (PRG No. 10)
311
General-purpose output
012
Program specification (PRG No. 20)
312
General-purpose output
013
Program specification (PRG No. 40)
313
General-purpose output
014
General-purpose input
314
General-purpose output
015
General-purpose input
315
General-purpose output
Input
Output
(Note) The numbers of I/O ports are as follows:
If DeviceNet and expansion I/O boards are used together, pay attention to the numbers of I/O
ports.
Inputs: 000 to 299 (maximum of 300 points)
Outputs: 300 to 599 (maximum of 300 points)
No.
Error name
Contents and Treatment
D77 Fieldbus error (Exception)
A communication board error was detected.
Reboot the XSEL controller. If the same error occurs again, please
contact us.
E1F I/O Assignment Parameter Error
It is a parameter setting error.
Check to see that a number out of the I/O port number (except
for -1) is not set to I/O Parameters No. 2 to 9, a number out of
indication is not input to I/O port start number, or a number out of
indication is not input to I/O Parameters No. 14 to 17. [Refer to
XSEL Controller Instruction Manual.]
E20 I/O Duplication Assignment Error
I/O assignment is duplicated.
Check to see that a number out of the I/O port number (except
for -1) is not set to I/O Parameters No. 2 to 9, a number out of
indication is not input to I/O port start number, or a number out of
indication is not input to I/O Parameters No. 14 to 17. [Refer to
XSEL Controller Instruction Manual.]
Check the number of the ports that I/O boards are mounted.
E21
I/O Assignment Number Overflow Error
I/O assignment has exceeded the specified range.
Check to see that a number out of the I/O port number (except
for -1) is not set to I/O Parameters No. 2 to 9, a number out of
indication is not input to I/O port start number, or a number out of
indication is not input to I/O Parameters No. 14 to 17. [Refer to
XSEL Controller Instruction Manual.]
Check the number of the ports that I/O boards are mounted.
E8F Fieldbus logic error
It is a logic error at the Fieldbus initializing.