background image

7

ICD6SG3

ICD9SG4

600

510

Gas Connection

Electrical Supply
Cord

107

860

510

Gas Connection

Electrical Supply
Cord

240

   NG 

 Universal 

LPG

1 Rapid burner  

 

11,5 MJ/h  

10.0 MJ/h

2 Semi-rapid burner  

6.3 MJ/h   

6.0 MJ/h

3 Auxiliary burner   

3.6 MJ/h   

3.6 MJ/h

4 Triple ring burner   

13.0 MJ/h  

13.0 MJ/h

8 Control knob for burner

TECHNICAL CHARACTERISTIC TABLES

The manufacturing firm refuses all responsibility for any possible imprecision in this booklet, due to 
misprints or clerical errors. It reserves the right to make all the changes that it will consider necessary in 
its own products, without effecting the essential characteristics of functionality and safety.

BURNERS

GAS

NORMAL 

PRESSURE

INJECTOR 

DIAMETER

TAPE BY 

PASS 

DIAMETER

NOMINAL 

HEAT INPUT

(MJ/h)

N° DESCRIPTION

KPa

1/100 mm

1/100 mm

Max.

Min.

1

RAPID

Universal LPG

2.75

85

40

10.0

2.4

Natural

1.00

155

Adjust.

11.5

1.7

2

SEMI-RAPID

Universal LPG

2.75

65

31

6.0

1.2

Natural

1.00

110

Adjust.

6.3

1.5

3

AUXILIARY

Universal LPG

2.75

52

27

3.6

0.9

Natural

1.00

80

Adjust.

3.6

0.9

4

TRIPLE 

CROWN

Universal LPG

2.75

95

60

13.0

4.5

Natural

1.00

160

Adjust.

13.0

3.4

Содержание ICD6SG3

Страница 1: ...COD 208228 REV1 28 05 2007 Gas Built in Hobs MODEL ICD6SG3 MODEL ICD9SG4 INSTALLATION AND OPERATION MANUAL ...

Страница 2: ...ing the equipment cut power supply off and make it cool down Make sure that air circulates around the gas equipment Insufficient ventilation produces a lack of oxygen In case of an intense or prolonged use of the equipment it may be necessary to improve aeration for example by opening a window or increasing the mechanical suction power if it exists The products of combustion must be discharged out...

Страница 3: ...re when overheated Do not spray aerosols in the vicinity of the appliance while it is in operation Do not store or use flammable liquids or items in the vicinity of this appliance Do not place unstable or deformed pots on the burner so as to prevent them from overturning or overflowing Make sure that pot handles are placed properly When the burner is started up check that the flameis regular and b...

Страница 4: ...alled to guarantee an adequate ventilation with the lower air entering with a cross section of at least 200cm2 and the higher air exiting with a cross section of at least 60 cm2 Fastening the top Every cook top is equipped with a special washer A set of hooks is also supplied for mounting the cook top Depending on the type of mounting surface the suitable type of mounting hook is supplied hook A o...

Страница 5: ...ce is suitable for Natural Gas and Uni versal LPG ensure that the available gas supply matches the Data Label When converting from Natural Gas to Universal LPG ensure that the NG regulator is removed and replaced with the Test Point Assembly An AGA Ap proved gas regulator suitable for a supply pressure of 2 75kPa should be part of the gas tank supply and the test point pressure should be adjusted ...

Страница 6: ...6 1 2 3 4 5 6A 6 8 7 9 10 10 A V ...

Страница 7: ...isprints or clerical errors It reserves the right to make all the changes that it will consider necessary in its own products without effecting the essential characteristics of functionality and safety BURNERS GAS NORMAL PRESSURE INJECTOR DIAMETER TAPE BY PASS DIAMETER NOMINAL HEAT INPUT MJ h N DESCRIPTION KPa 1 100 mm 1 100 mm Max Min 1 RAPID Universal LPG 2 75 85 40 10 0 2 4 Natural 1 00 155 Adj...

Страница 8: ...8 PRODUCT SERVICE PHONE NUMBER 1800 805 300 ...

Отзывы: