17
W210 Calibra on Process
1.
Hold down the green
Weigh
bu on and the blue
Zero
bu on while turning the mode selector
switch from (Off) to
F
(Fine).
2.
CAL
-
0
displays on the Weighing screen
3.
Check there is no load on the load bars.
Press the blue
Zero
bu on.
CAL
-
L
displays on the Weighing screen.
4.
Apply the known test load to the scale.
Once the load is on and si ng stable, press the green
Weigh
bu on.
The calculated weight displays on the screen.
5.
To
increaseÊ
the displayed weight: Press the green
Weigh
bu on to
increaseÊ
the displayed
weight in 1 kg increments.
To decrease the displayed weight: Press the blue
Zero
bu on to
decreaseÊ
the displayed
weight in 1 kg increments.
6.
Ensure the displayed weight equals the known test weight value.
Turn the mode selector switch from
F
(Fine) to
A
(Auto).
SAVE
displays on the Weighing screen.
Press the green
Weigh
bu on to save the new span value.
DONE
displays on the Weighing screen, the red light turns on. Turn the scale off
7.
Exit without saving new span value
Turn the mode selector switch from
F
(Fine) to (Off) or press
the blue
Zero
bu on to return to Fine mode.
Please reference the Gallagher website for
more informa on on the W210 Weigh Scale
www.gallagher.eu/en_gb