The 

Radiation  meter  EcoLife  Pro1

  is  a  hand-held  device,  produced  to  control  the 

background radiation indoors and outdoors by measuring: 

 
-  the ambient dose of photon and gamma radiation and the ambient dose rate; 
-  the activity concentration of beta and gamma radioactive nucleus in substances. 

 
Note:  
the  ambient  dose  is  the  amount  of  radiation  received  by  a  person  staying  at  the 

measuring point.  

 
The 

Appendix

  is  to  get  you  acquainted  with  the  general  information  about  the  radiation 

nature and the material-radiation interaction.  

 

Attention! 

Read  this  manual  carefully  in  order  to  use  the  product  efficiently  and  safety 

for a long time. 

Follow  the  rules,  restrictions  and  instructions  contained  in  the  manual  to  increase  the 

lifespan of the equipment and to use it most effectively.  

The  manufacturer's  warranty  will  become  invalid  prematurely  if  the  operator  of  the 

equipment does not follow the storage and transportation 

instructions

.  

 
Attention! 

While  measuring  the  natural  background  radiation  the  readings  of  even  two 

equal  radiation  meters  may  differ  because  the  natural  background  is  characterized  by  the  low 
density  of  particle  flow  and  electromagnetic  energy.  The  lower  density  of  the  flow,  the  fewer 
particles is detected by the sensor per unit of time, that’s why you may take the major variety of 
different readings. This situation is similar to the rain in everyday life. When there is a bit of rain 
it’s difficult to detect how many drops drip per second by hand (there may be 2 drops, more or 
no one). When the rain is heavy, there will be a constant number of drops per second.

 

 

Attention! 

The device is intended for domestic use only. The readings taken by it can’t be 

used for making official reports on the radiation situation or pollution rate.  

 

Warning! 

After storing the product in a cold place or transporting it in winter you should 

keep the device at the room temperature for 2 hours before operating.   

 

Warning! 

Demand  to  perform  a  functional  test  before  purchase.  Also  ensure  that  the 

warranty sticker placed into the battery compartment is not damaged. Control the contents of the 
box  according  to  the  1.3.1  article of  this  manual. Ensure the  warranty card  is  signed,  dated and 
stamped.  

 

1.

 

Specification and operation 
 

1.1. Correct use and application area 
 

The

 Radiation meter EcoLife Pro1 

is produced to control the radiation environment and 

can be used  

-

 

as an individual detector of the ambient dose and the ambient dose rate of  gamma and X 

radiation, including beta-particle flow; 

-

 

as an exploratory detector of the ambient dose and the ambient dose rate of  gamma and 

X  radiation,  including  beta-particle  flow,  that’s  used  to  search  for  the  objects  polluted  and  the 
radiation sources; 

-

 

to  control  the  radioactive  pollution  of  currency  notes,  goods,  freights,  foods,  toys, 

materials and the packaging of them. 

 

Содержание 62252

Страница 1: ...Package and transportation 6 Proof of acceptance 7 Manufacturer s warranty 8 Certification information Warranty Card Appendix General information of the radiation nature and the material radiation in...

Страница 2: ...ifferent readings This situation is similar to the rain in everyday life When there is a bit of rain it s difficult to detect how many drops drip per second by hand there may be 2 drops more or no one...

Страница 3: ...accumulated dose selecting the unit measures roentgen Sievert setting and changing the alarm sound of the ambient dose rate threshold audiovisual warning of the ambient dose rate threshold excess sett...

Страница 4: ...re than 105 58 18 5 Mass with batteries grams not more than 110 1 3 Contents of the box 1 3 1 The table below gives the information about parts of the product and the delivery set Table 2 Name number...

Страница 5: ...nging from 10 to 80 seconds depending on the radiation rate The displayed values are automatically changing and being averaged by the microprocessor This averaging process is displayed by the measurem...

Страница 6: ...iation dose considered safe During the life the accumulated dose value must be below 100 700 millisieverts summarized according to the local radiation background 1 4 4 Control buttons are used to swit...

Страница 7: ...edure To prepare the product for working you should loosen the screw and remove the battery compartment cover no 3 Fig 2 install the batteries respecting polarities Fig 4 place back the battery compar...

Страница 8: ...button come back to the Measurement settings menu Fig 8 for further settings 2 3 1 4 Setting the threshold of the ambient dose rate above which the device sounds because the radiation level is high wh...

Страница 9: ...opposite the chosen brightness and the screen brightness will be changed according to your choice by pushing the button come back to the Screen settings menu fig 9 for further settings 2 3 1 8 Setting...

Страница 10: ...hing the buttons choose the line BUTTONS SOUND and confirm your choice by pushing the button or by pushing the buttons and choose the value ON or OFF to switch the buttons sound on and off and confirm...

Страница 11: ...rgy of the batteries when user forgets to switch off the device For settings you should when you are in the Main menu 7 by pushing the buttons choose the line SETTTINGS and confirm your choice by push...

Страница 12: ...e the line SETTTINGS and confirm your choice by pushing the button or in the opened submenu by pushing the buttons and choose the line ACCUMULATOR and confirm your choice by pushing the button or by p...

Страница 13: ...dio signal passing frequency occur At the same time the ambient dose value is raising in the upper right corner of the screen and the columns at the radiation environment time based historical graphs...

Страница 14: ...e the natural radiation background normal for the location it indicates that the object you investigate is polluted by radiation To define the ionization radiation source you should remove the working...

Страница 15: ...pair should be carried out by the dealer 5 Package and transportation Every Product delivery set see Table 2 is packaged in individual corrugated fiberboard box The moving of contents of the box is no...

Страница 16: ...or the authorized Distributor shall replace or repair the products broken down during the guaranteed use period at the expense of them 7 5 This warranty shall be void if guaranteed use period is over...

Страница 17: ..._________________________________________________________________________ Sale Date _________________________________________________________________________ Vendor s stamp and signature _____________...

Страница 18: ...es caused to biological tissues by ionizing radiation exposure depend on the dose of absorbed radiation energy To characterize it the term absorbed dose is used i e the energy absorbed by the unit of...

Страница 19: ...The equivalent dose rate H is defined by the formula H dH dT where dT is a period of time In the SI system the equivalent dose rate H is measured by Sievert per second Sv s 1 Sv s 100 Rem s 1 Sv s R s...

Отзывы: