background image

«I4Technology» OOO (Ltd.) 

 

Radiation meter EcoLife  Pro1 

 

Instruction manual INTС.412113.001 RE 

 
 

 

 
Table of contents  
 

Introduction  
 
1.

 

Specification and operation  

1.1.

 

 Correct use and application area  

1.2.

 

 Technical features 

1.3.

 

 Contents of the box 

1.4.

 

 Internal design and operating 

1.5.

 

 Identification and sealing  

 
2.

 

Correct use 

2.1.

 

 Use limits  

2.2.

 

 Pre-starting procedure  

2.3.

 

 Operation  

 
3.

 

Technical service 

4.

 

Failure table 

5.

 

Package and transportation 

6.

 

Proof of acceptance 

7.

 

Manufacturer’s warranty 

8.

 

Certification information 

 

Warranty Card 
 

Appendix.

  General  information  of  the  radiation  nature  and  the  material-radiation 

interaction.  

 

This  manual  is  to  get  you  acquainted  with  the 

Radiation  meter  EcoLife  Pro1 

internal 

design,  working  principles  and  rules  of  operation  (correct  use,  maintenance,  storage  and 
transportation). 

 
In  production the  device  construction  and  electrical  scheme  can  be  modified. It  does  not 

impact the technical and metrological features of the product, - that’s why the modifications are 
not mentioned in this manual.  

Содержание 62252

Страница 1: ...Package and transportation 6 Proof of acceptance 7 Manufacturer s warranty 8 Certification information Warranty Card Appendix General information of the radiation nature and the material radiation in...

Страница 2: ...ifferent readings This situation is similar to the rain in everyday life When there is a bit of rain it s difficult to detect how many drops drip per second by hand there may be 2 drops more or no one...

Страница 3: ...accumulated dose selecting the unit measures roentgen Sievert setting and changing the alarm sound of the ambient dose rate threshold audiovisual warning of the ambient dose rate threshold excess sett...

Страница 4: ...re than 105 58 18 5 Mass with batteries grams not more than 110 1 3 Contents of the box 1 3 1 The table below gives the information about parts of the product and the delivery set Table 2 Name number...

Страница 5: ...nging from 10 to 80 seconds depending on the radiation rate The displayed values are automatically changing and being averaged by the microprocessor This averaging process is displayed by the measurem...

Страница 6: ...iation dose considered safe During the life the accumulated dose value must be below 100 700 millisieverts summarized according to the local radiation background 1 4 4 Control buttons are used to swit...

Страница 7: ...edure To prepare the product for working you should loosen the screw and remove the battery compartment cover no 3 Fig 2 install the batteries respecting polarities Fig 4 place back the battery compar...

Страница 8: ...button come back to the Measurement settings menu Fig 8 for further settings 2 3 1 4 Setting the threshold of the ambient dose rate above which the device sounds because the radiation level is high wh...

Страница 9: ...opposite the chosen brightness and the screen brightness will be changed according to your choice by pushing the button come back to the Screen settings menu fig 9 for further settings 2 3 1 8 Setting...

Страница 10: ...hing the buttons choose the line BUTTONS SOUND and confirm your choice by pushing the button or by pushing the buttons and choose the value ON or OFF to switch the buttons sound on and off and confirm...

Страница 11: ...rgy of the batteries when user forgets to switch off the device For settings you should when you are in the Main menu 7 by pushing the buttons choose the line SETTTINGS and confirm your choice by push...

Страница 12: ...e the line SETTTINGS and confirm your choice by pushing the button or in the opened submenu by pushing the buttons and choose the line ACCUMULATOR and confirm your choice by pushing the button or by p...

Страница 13: ...dio signal passing frequency occur At the same time the ambient dose value is raising in the upper right corner of the screen and the columns at the radiation environment time based historical graphs...

Страница 14: ...e the natural radiation background normal for the location it indicates that the object you investigate is polluted by radiation To define the ionization radiation source you should remove the working...

Страница 15: ...pair should be carried out by the dealer 5 Package and transportation Every Product delivery set see Table 2 is packaged in individual corrugated fiberboard box The moving of contents of the box is no...

Страница 16: ...or the authorized Distributor shall replace or repair the products broken down during the guaranteed use period at the expense of them 7 5 This warranty shall be void if guaranteed use period is over...

Страница 17: ..._________________________________________________________________________ Sale Date _________________________________________________________________________ Vendor s stamp and signature _____________...

Страница 18: ...es caused to biological tissues by ionizing radiation exposure depend on the dose of absorbed radiation energy To characterize it the term absorbed dose is used i e the energy absorbed by the unit of...

Страница 19: ...The equivalent dose rate H is defined by the formula H dH dT where dT is a period of time In the SI system the equivalent dose rate H is measured by Sievert per second Sv s 1 Sv s 100 Rem s 1 Sv s R s...

Отзывы: