INSTALLATION 

1. Refer to Fig. 1, loosen the Screw A on the bottom box by about 5 turns counter-clockwise
2. Refer to Fig. 2 & Fig. 3, detach the bottom box of the smoke detector.
3. Refer to Fig. 3, open the cover of the battery compartment, connect supplied 9V battery and then close the cover.
4. Re-assemble  the  bottom  box  with  the  main  body.  The  marks  should  be  at  the  position  shown  in  Fig.  5  after

combination. And then tighten the Screw A.

5.

Keep pressing the Clear/Enroll Button on 

i4H-

LS-20 for over 3 seconds and then release it, the 

i4H-

LS-20 would

 

keep beeping and all LEDs blink. This means the system is ready for enrolling device.

6. Within 30 seconds press the TEST button of the 

i4H-

SM-3S for 2 seconds. If you hear 3 short beeps from the 

i4H-

LS-20

 

soon later then enrolling successes, otherwise you will hear one  long beep after 30 seconds that means enrolling fails,

 

you 

have to repeat enrolling action.
Note: Avoid activating any other sensors during the 30 seconds Device Enroll period.
Remarks:  In  case  you  have  to  change  the  device‟s  attribute,  please  do  it  on  the  cloud  web  directly,  or  refer  to

 

HyperSecureLink software user guide to change it by computer.

7. Locate the smoke detector properly, and fixed the bracket with the two supplied screws on the ceiling. And then mount

the smoke detector on the bracket.

Note: Keep the smoke detector within effective radio range away from the base unit.

8. Press the “

TEST

” button, and check if the base unit is activated.

Note:

 

1) The LED starts flashing after a few seconds when smoke is detected, then the internal buzzer sounds

and activates the base unit it after 10 seconds. 

2) The LED flashes every 

43

 seconds to indicate the detector is in standby mode, and it beepsperiodically

if 9V battery goes too low. Replace the battery when these beeps occur. 

3) Maintenance  at  least  once  a  year  is  essential.  Open  the  cover  then  clean  the  sensing  chamber  with

vacuum cleaner carefully.

4) SM-3S comes with cover latches that prevent the cover from closing if no battery is installed.

PREFERRED LOCATION 

LOCATIONS TO BE AVOIDED 

Do NOT locate detector in: 

The Kitchen: Smoke from cooking might cause an unwanted alarm.

Near Ventilating fan, Fluorescent lamp or Air-Conditioning equipment: Air drafts from them may affect the sensitivity
of the detector.

Near Ceiling beams or over Cabinet: Stagnant air in this area may affect the sensitivity of the detector.

In the peak of an 'A' frame type of ceiling.

SPECIFICATIONS: 

Detection: 

Photo-electric Chamber 

Thermistor for heat, alarm level:

 

above

 

57+/- 3

 (Only for 

i4H-

SM-3SH) 

Either of smoke or heat alarm would trigger the detector 

Power: 

9V Battery 

Supervision:

 Sends heartbeat signal at 60-minute intervals. When Tamper or 

Low -Battery condition is detected, it reports automatically. 

Current Consumption:

 10uA@ standby, 16mA@ activation 

Battery Life: 

About 1~1.5 years 

Working Temperature: 

0

 ~ 50

 

Ambient Relative Humidity:

 10%

85% 

Alarm Sound Level: 

85dB@3m 

Indicator Light: 

LED flashes every 32 seconds approximately. 

Low Battery: 

Beep every 32 seconds approximately. 

Actuation Indicator: 

LED ON, Buzzer ON 

Size:

 φ101mm x H 52mm

 

Weight: 

About 126g (w/o battery)

 

BATH
ROOM

LIVING ROOM

BED
ROOM

BED 
ROOM

STORE
ROOM

DINNER
ROOM

In the center of the ceiling

At the top
of a stairway

0.6m

At least 0.6m
from the wall

1.2 m

In the ceiling of
the corridor is
less than 1.2 m
in width