77
INFO
Fan install
Fan (<string>) is installed
ERROR
Fan not present
Fan (<string>) is not present
ERROR
Fan over speed
Fan (<string>) is over speed
WARNING
Thermal level 1
System temperature (<string>) is higher.
ERROR
Thermal level 2
System Overheated (<string>)!!!
ERROR
Thermal level 2
shutdown
System Overheated (<string>)!!! The system will auto-shutdown
immediately.
ERROR
Thermal level 2 CTR
shutdown
The controller will auto shutdown immediately, reason
[Overheated (<string>)].
WARNING
Thermal ignore value
Unable to update thermal value on <string>
WARNING
Voltage level 1
System voltage (<string>) is higher/lower.
ERROR
Voltage level 2
System voltages (<string>) failed!!!
ERROR
Voltage level 2
shutdown
System voltages (<string>) failed!!! The system will auto-
shutdown immediately.
ERROR
Voltage level 2 CTR
shutdown
The controller will auto shutdown immediately, reason [Voltage
abnormal (<string>)].
INFO
UPS OK
Successfully detect UPS
WARNING
UPS fail
Failed to detect UPS
ERROR
UPS AC loss
AC loss for system is detected
ERROR
UPS power low
UPS Power Low!!! The system will auto-shutdown immediately.
WARNING
SMART T.E.C.
Disk <slot> S.M.A.R.T. Threshold Exceed Condition occurred for
attribute <string>
WARNING
SMART fail
Disk <slot>: Failure to get S.M.A.R.T information
WARNING
RedBoot failover
RedBoot failover event occurred
WARNING
Watchdog shutdown
Watchdog timeout shutdown occurred
WARNING
Watchdog reset
Watchdog timeout reset occurred
RMS Events
Level
Type
Description
INFO
Console Login
<username> login from <IP or serial console> via Console UI
INFO
Console Logout
<username> logout from <IP or serial console> via Console UI
INFO
Web Login
<username> login from <IP> via Web UI
INFO
Web Logout
<username> logout from <IP> via Web UI
INFO
Log clear
All event logs are cleared
WARNING
Send mail fail
Failed to send event to <email>.
LVM Events
Level
Type
Description
INFO
RG create OK
RG <name> has been created.
INFO
RG create fail
Failed to create RG <name>.
INFO
RG delete
RG <name> has been deleted.
INFO
RG rename
RG <name> has been renamed as <name>.
INFO
VD create OK
VD <name> has been created.
INFO
VD create fail
Failed to create VD <name>.
INFO
VD delete
VD <name> has been deleted.
INFO
VD rename
Name of VD <name> has been renamed to <name>.
INFO
VD read only
Cache policy of VD <name> has been set as read only.
INFO
VD write back
Cache policy of VD <name> has been set as write-back.
INFO
VD write through
Cache policy of VD <name> has been set as write-through.
INFO
VD extend
Size of VD <name> extends.
INFO
VD attach LUN OK
VD <name> has been LUN-attached.
INFO
VD attach LUN fail
Failed to attach LUN to VD <name>.
INFO
VD detach LUN OK
VD <name> has been detached.
INFO
VD detach LUN fail
Failed to attach LUN from bus <number>, SCSI ID <number>,