56
ration is smaller than the setting value, the system will ignore the target which motion trigger.
5.
Specify the notify method (Such as Trigger alarm output, move PTZ camera position, notify via
email) when an event occur.
6.
Click
Save
to change the setting.
VQD (Video Quality Diagnose):
Click this button to setup Video quality detection function.
Enable:
Enable or disable the video diagnose function.
Arming Schedule:
Arm schedule of enable area detection. Check/Uncheck from Monday to
Sunday, each date can has its own trigger period.
Image Detection Type:
There are 5 kind video quality detection modes- Color Cast, Image Blur,
Image Bright, Image Dark and video loss. The setting value higher and more sensitivity. Choose
one for the detection type.
Email:
Check “Email” and once the event triggers that it will send Email to setting email address.
Alarm Output:
Check “Alarm output” and once the event triggers, the camera will linkage to alarm
output.