1.

 

 INTRODUCTION 

 

The purpose of this manual is to ease the installation, the operation and the routine maintenance activities 
of the 

SC 

side channel blowers and exhausters

This  manual  must  be  completely  read  and  understood  by  all  operating  and  servicing  personnel  before 
beginning with the installation and the start-up of the machine in order to grant the correct functioning and 
personnel security. 

This manual must be always available at the site of operation of the machine. 

 

    WARNING! 

These  instructions must be strictly observed. Any improper use carried out  by unskilled 
and/or unauthorized personnel could cause serious damages to the machine and serious 
injuries to people, even death! 

 

The Technical and Service Departments are available for any technical assistance or clarification you may 
need. Do not hesitate to contact us. 

 

2.

 

REVIEW OF THE SHIPPING DOCUMENTS 

 

When receiving the goods, it is necessary to inspect and check them against the shipping documents. Make 
sure that no shipping damages are occurred to the equipment during transportation. 

Accessories come loose and have to be mounted before start-up. 

 

 

3.

 

WARRANTY 

 

The  goods related with this instruction manual are free from defects in materials and workmanship. The 
warranty  period  is:  twelve  months  from  the  date  of  their  initial  use  or  eighteen  months  from  delivery, 

whichever expires first (“Warranty Period”).

 

The  warranty  covers  those  parts  of  the  machine  that  are  defective  in  either  materials,  construction  or 
workmanship. The warranty does not cover wearing parts (e.g. bearings and lip seals), defects arising from 
chemical corrosion or galvanic action, from misuse or wrong interpretation of the instructions contained in 
this manual, or from modifications or repairs not expressly authorized in writing by I.VA.CO. SRL. 

Any claims for defects must be made in writing and the purchaser is not entitled to withhold or delay any 
payments or cancel any contract as a result of those defects. 

Содержание SC Series

Страница 1: ...01MF SC401MF SC431MF SC501MF SC531MF SC601MF SC631MF SC602PF SC701MF SC731MF SC802PF SC901MF SC931MF SC942PF SC951MF SC302SF SC402SF SC502SF SC602SF SC902SF SC902PF ORIGINAL INSTRUCTIONS English I VA CO Srl Via delle Brigole 33 23877 Paderno d Adda LC Italy www ivaco it info ivaco it 39 039 9281084 ...

Страница 2: ...AL CONNECTIONS DRAWINGS 12 4 ACCESSORIES INSTALLATION DRAWING 13 START UP ADJUSTMENT 14 MAINTENANCE 14 1 CLEANING 14 1 1 SILENCER ELEMENTS REPLACEMENT 14 2 SEALING RINGS AND BEARINGS REPLACEMENT 15 OPERATING PROBLEMS AND TROUBLE SHOOTING 16 SHUT DOWN PERIOD 17 MACHINE SCRAP AND DISPOSAL 18 REPAIR 19 SPARE PARTS ATTACHMENTS EXPLODED ASSEMBLY DRAWINGS WITH PARTS LIST EU DECLARATION KLIXSON SPECIFICA...

Страница 3: ...MENTS When receiving the goods it is necessary to inspect and check them against the shipping documents Make sure that no shipping damages are occurred to the equipment during transportation Accessories come loose and have to be mounted before start up 3 WARRANTY The goods related with this instruction manual are free from defects in materials and workmanship The warranty period is twelve months f...

Страница 4: ...epresentative the warranty wiII become void and unenforceable and I VA CO SRL shall not be liable for any damage to anything or anybody that could happen after any unauthorized operation or replacement I VA CO SRL shall not be liable for any damage directly or indirectly arising in connection with the machine non use during the repair under guarantee I VA CO SRL shall not be liable for any damage ...

Страница 5: ... power supply and inform the plat personnel responsible for operation 6 TRANSPORT SC blowers and exhausters must be transported by adequate equipment suitable to their weight and packing dimensions and in accordance with the safety standard on force When transporting installing and performing maintenance it is important to grant a safe lifting of the machine using serviceable lifting slings instal...

Страница 6: ...equent progressive increase of energy The pitch of the helicoidally trajectory changes in proportion with pressure variation between suction and discharge The pitch is able to self calibrate according to the load acting on the fluid The gas is free of pollution and keeps a linear flow without pulsations The absence of vibrations and a low noise level are further advantages and contribute to ease t...

Страница 7: ...rated place where the ambient temperature is between 15 40 C humidity 80 at a maximum height of 1000 m above sea level When installing at different conditions it is necessary to consider the variation of gas characteristics pressure and weight and the downgrade of the motor s efficiency Surface treatments on the machine components are needed whenever humidity exceeds 80 If installed outdoors must ...

Страница 8: ...SO 3744 measured at 1 m distance with no vacuum and or pressure restriction valve installed Tolerance 3 dB A Sound power level LW according to EN ISO 3744 Tolerance 3 dB A 12 CONNECTIONS WARNING All connections must be carried out by trained and specialized personnel 12 1 CONNECTION TO THE PLANT Connect the machine to the piping system by flexible connectors avoiding rigid connections that may cau...

Страница 9: ... be preferred It is advisable to install a safety valve to avoid pressure overloads Connect the motor and check the rotating direction before piping connection The shaft direction of rotation is marked by an arrow on the fan guard of the electric motor The gas delivery direction is marked with arrows on both suction and discharge connections Pay attention not to confuse the suction and the dischar...

Страница 10: ... phase motors with a rated voltage of 230V at 50Hz According to IEC 34 specification a 5 line voltage is allowed for motors with any other rated voltage at 50Hz and for any voltage at 60Hz All SC blower and exhauster are equipped with a KLIXON thermal protector See attached specification which must be connected to the main terminal box Warranty will be void in case of either misconnection or wrong...

Страница 11: ...NDA 1 SIDE CHANNEL BLOWER EXHAUSTER 10 METALLIC FILTER 2 VACUUM PRESURE GAUGE 11 PIPING CONNECTIONS 3 SAFETY VALVE 12 PIPE CONNECTION 4 IN LINE FILTER 5 CARTRIDGE FILTER 6 SILENCER 7 IN LINE SILENCER 8 VACUUM PRESSURE GAUGE KIT 9 VALVE KIT 13 START UP ...

Страница 12: ... missing phase frequent start ups excessive voltage variations clogging of the rotor the overload overheat protection is compulsory in order to prevent overload Adjust the protective motor according to the nominal value on the nameplate as maximum value At machine start up it s necessary To check the operating pressure by a pressure gauge or a vacuum gauge To check the calibration of the safety va...

Страница 13: ...rt of the machine with compressed air Deposit of dust on external blower surface avoid an adequate thermal exchange and can cause an overheating of the interior Clean the ventilation grid of the motor fan cover Dirt on motor fan cover reduces the air flow and causes motor overheating Every 10 15 days during operation it is advisable to clean the filter cartridge If the machine operate in a high du...

Страница 14: ... the screws 45 holding the flange Unscrew the tie rod 26 remove the silencer paying attention not to lose the flat gasket 22 Replace the net silencer 23 and the silencer insert 24 Reassemble the machine reversing the disassembly procedures 14 2 SEALING RINGS AND BEARINGS REPLACEMENT The sealing rings lose the sealing capacity when exceeding their lifetime max 2 years thus allowing fluid losses At ...

Страница 15: ...gged Check and replace the motor Reduce throttling if necessary clean filters silencer and connection pipes See point 2 2 4 The machine does not deliver differential pressure or the pressure is too low 4 1 Leak in system 4 2 Wrong sense of rotation 4 3 Wrong frequency 4 4 Shaft seal defective 4 5 Different density of gas 4 6 Change in blade profile due to dirt Seal the leak Reverse direction of ro...

Страница 16: ...ds on force 18 REPAIR Due to the accuracy required in performing disassembly and assembly procedures of SC blowers and exhausters they must be carried out only by trained and skilled personnel If necessary the machine can be returned back to I VA CO SRL for repair recommended action 19 SPARE PARTS To order spare parts necessary to repair the following information are mandatory Part description Ite...