![I.VA.CO. SC Series Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/i-va-co/sc-series/sc-series_operating-and-maintenance-manual_603485010.webp)
I.VA.CO. Srl
10
Ed.12/2016
Three-phase motor single phase motor
Three-phase motors have a rated voltage
, AT 50Hz, of 230VΔ/400VY, and they can accept a ±
10% line
voltage variation, according to IEC 38 specification.
The same line voltage variation is allowed for single-phase motors with a rated voltage of 230V at 50Hz.
According to IEC 34 specification a ± 5% line voltage is allowed for motors with any other rated voltage at
50Hz and for any voltage at 60Hz.
All SC blower and exhauster are equipped with a KLIXON thermal protector. (See attached specification),
which must be connected to the main terminal box. Warranty will be void in case of either misconnection
or wrong connection of the KLIXON.
12.4 ACCESSORIES INSTALLATION DRAWING