I.VA.CO. ICP Series Скачать руководство пользователя страница 7

5.0    PROBLEM SOLVING 

5.1    Problem

   

    Compressor does not reach capacity. 

   

5.1.1    Possible Cause 

Inlet screen (mesh) of the inlet filter clogged with debris. 

Remedy

 : check inlet filter element and clean screen (mesh) by compressed air or wash it. 

   

5.1.2    Possible Cause 

Pipe work is too long or small. 

Remedy

 : Use the bigger diameter pipe and shorten the lines length if possible. 

5.2    Problem

 

    Compressor runs over set pressure. 

     

5.2.1    Possible Cause 

Pressure Regulator or Safety Valve set over the set point, or is out of order. 

Remedy

 : Set the point again or replace it with new one. 

5.3    Problem 

Compressor does not reach the set pressure. 

5.3.1    Possible Cause 

Leak on the compressor or system. 

Remedy

 : Check the leak on the compressor or system.

5.4    Problem 

Compressor runs very noisy. 

    5.4.1    Possible cause 

Contamination of the claws or chamber. 

Remedy 

: Clean the pumping chamber and the claws. 

    5.4.2    Possible cause 

Coupling insert is worn. 

Remedy

 : replace coupling insert in motor/compressor coupling. 

   

5.4.3    Possible Cause 

Bearing noise 

Remedy

 : replace bearings or call service agent for service or exchange program. 

5.4.4    Possible Cause 

Pressure regulator or safety valve noise 

Remedy

 : replace Pressure regulator or Safety valve 

5.5    Problem 

    Compressor will not start. 

   

5.5.1    Possible Cause 

Supply voltage is not proper or is overloaded. Motor starter overload settings are too low or 
improper; fuses are burned; wire size is to small or too long causing a voltage drop. 

Remedy

 : check voltage supply; overload settings in motor starter for size and settings     

according to motor nameplate. Install proper size wire. If ambient temperature is high,     
use the next larger size overloads, or adjust settings 5% above motor nameplate value.

Remedy

. Repair or replace if needed or call service agent for service or exchange program. 

Содержание ICP Series

Страница 1: ...llation and Operating Manual ICP SERIES VACUUM PUMP MODEL 100 2 2017 REV1 I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy Tel 39 039 9281084 info ivaco it www iva...

Страница 2: ...Labels 3 0 OPERATION 3 1 Start up 3 2 Stopping the compressor 3 3 Ambient operating conditions 4 0 MAINTENANCE 4 1 Compressor Lube Oil level type quantity change 4 2 Inlet filter 4 3 Maintenance char...

Страница 3: ...ling The ICP Series compressors are identical in internal construction to ICV vacuum pump but are outfitted with different inlet and outlet accessories to allow for operation as a compressor 1 2 Unpac...

Страница 4: ...g pipe lines result in a reduced compressor capacity Compressors operating in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve in...

Страница 5: ...Warning labels and its explanation Following warning labels are shown and attached on ICP series compressor 2 2 1 Read and Understand a manual Read and understand operator s manual before using this...

Страница 6: ...epending on the mounting position of the filter be careful not to allow accumulated foreign material to fall in the pump suction inlet when removing the filter cartridge Horizontal filter installation...

Страница 7: ...ation of the claws or chamber Remedy Clean the pumping chamber and the claws 5 4 2 Possible cause Coupling insert is worn Remedy replace coupling insert in motor compressor coupling 5 4 3 Possible Cau...

Страница 8: ...DATA Model ICP 100 M3 Hour 60Hz 120 50Hz 100 Press conti Bar 60Hz 1 4 2 2 50Hz 0 8 1 4 2 2 Kw 60Hz 4 8 6 5 50Hz 3 4 5 5 RPM 60 50Hz RPM 3450 2850 Voltage Available V 208 230 460V 220 380V 230 400V 40...

Страница 9: ...ASS y DRAWING ICP100 IF IEC ICP ICP ICP ICP ICP ICP ICP...

Страница 10: ...ASS y DRAWING ICP 100 IF NEMA ICP ICP ICP ICP...

Страница 11: ...5 Shield Cover Front with mat 1 213 Hexagon Bolt M12 x 25 4 25 Key for Gear 2 96 Accoustic Mat for Shield Cover front and Side 1 214 Hexagon Bolt NEMA only 4 26 Key for Coupling 1 97 Foot Rubber 30x20...

Страница 12: ...I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy 39 039 9281084 info ivaco it www ivaco it...

Отзывы: