1.0  INSTALLATION 

1.1 General description 

   

The ICP compressor is dry and contactless machines, enclosed in acoustic sound shied and designed to 

have cooling air passed through the sound shied by fan. The warm air is exhausted through the vent. The 
ICP is constructed in modular construction consisting of two compartments: pumping and gear chambers 
separated by using labyrinth seals. In the pump chamber, as two rotary claws rotate in opposite direction, 
the air sucked in, shall be compressed and discharged under pressure. In the gear chamber (box), two 
gears for synchronizing of claws rotation will be located with oil lubrication. For reduction of the noise, inlet 
silencer shall be installed in compressor inlet side. For a protection of overload, a pressure safety valve or 
regulating valve is installed in exhaust. The compressors are directly driven by a flanged motor via a 
coupling. The ICP Series compressors are identical in internal construction to ICV vacuum pump, but are 
outfitted with different inlet and outlet accessories to allow for operation as a compressor. 

1.2

 

Unpacking

Inspect the box and compressor carefully for any signs of damage incurred in transit. 

1.3    Location 

    Install the compressor in a horizontal position on a level surface so that it can be evenly supported on its         

rubber feet. Leave 30 ~ 45 cm of access around the compressor to allow proper cooling. Also, adequate 
ventilation must be provided for the cooling for the compressor and motor. 

    Allow access to the oil sight glass in order to inspect the oil level regularly, and the oil fill and oil drain port for 

easy service. 

 

1.4    Power Requirements 

A schematic diagram for the electrical motor terminal connections is located in the junction box of the 

motor or on the motor nameplate. Typical wirings for Three Phase Motors are as below:

 

Wiring Scheme- Three Phase Motor 

Delta Connection 

Low Voltage 

L1 

L2 

L3 

W2 

U2 

V2 

U1 

V1 

W1 

Star Connection 

High Voltage 

L1 

L2 

L3 

W2 

U2 

V2 

U1 

V1 

W1 

Содержание ICP Series

Страница 1: ...llation and Operating Manual ICP SERIES VACUUM PUMP MODEL 100 2 2017 REV1 I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy Tel 39 039 9281084 info ivaco it www iva...

Страница 2: ...Labels 3 0 OPERATION 3 1 Start up 3 2 Stopping the compressor 3 3 Ambient operating conditions 4 0 MAINTENANCE 4 1 Compressor Lube Oil level type quantity change 4 2 Inlet filter 4 3 Maintenance char...

Страница 3: ...ling The ICP Series compressors are identical in internal construction to ICV vacuum pump but are outfitted with different inlet and outlet accessories to allow for operation as a compressor 1 2 Unpac...

Страница 4: ...g pipe lines result in a reduced compressor capacity Compressors operating in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve in...

Страница 5: ...Warning labels and its explanation Following warning labels are shown and attached on ICP series compressor 2 2 1 Read and Understand a manual Read and understand operator s manual before using this...

Страница 6: ...epending on the mounting position of the filter be careful not to allow accumulated foreign material to fall in the pump suction inlet when removing the filter cartridge Horizontal filter installation...

Страница 7: ...ation of the claws or chamber Remedy Clean the pumping chamber and the claws 5 4 2 Possible cause Coupling insert is worn Remedy replace coupling insert in motor compressor coupling 5 4 3 Possible Cau...

Страница 8: ...DATA Model ICP 100 M3 Hour 60Hz 120 50Hz 100 Press conti Bar 60Hz 1 4 2 2 50Hz 0 8 1 4 2 2 Kw 60Hz 4 8 6 5 50Hz 3 4 5 5 RPM 60 50Hz RPM 3450 2850 Voltage Available V 208 230 460V 220 380V 230 400V 40...

Страница 9: ...ASS y DRAWING ICP100 IF IEC ICP ICP ICP ICP ICP ICP ICP...

Страница 10: ...ASS y DRAWING ICP 100 IF NEMA ICP ICP ICP ICP...

Страница 11: ...5 Shield Cover Front with mat 1 213 Hexagon Bolt M12 x 25 4 25 Key for Gear 2 96 Accoustic Mat for Shield Cover front and Side 1 214 Hexagon Bolt NEMA only 4 26 Key for Coupling 1 97 Foot Rubber 30x20...

Страница 12: ...I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy 39 039 9281084 info ivaco it www ivaco it...

Отзывы: