4.1.2 Gear Oil Type and Quantity
See section 1.5 - Oil Filling - for details on oil type and quantity
4.1.3 Oil Change
Under normal ambient conditions with proper Gear Oil, it is recommended to change the oil every 10,000
operating hours. It is necessary to make the first oil change between 500 ~1000 operating hours..
Caution: If different brand oil is being filled, the old oil must be drained completely from the gear box.
Caution: Above interval of lubrication is based on ambient temperature of 20
°
C. At 40
°
C ambient
temperature operation, it may be shorten to half.
4.2 Inline (Inlet) Filter
Check inline (inlet) filter on a weekly basis. The filter cartridge should be cleaned or replaced when
dirty. Consult service agent for replacement element information.
Caution: Depending on the mounting position of the filter, be careful not to allow accumulated
foreign material to fall in the pump suction inlet when removing the filter cartridge. Horizontal filter
installation is recommended to prevent this.
4.3 Maintenance Chart
Weekly:
Check inline inlet filter element. More often if high particulates in inlet stream
Monthly:
Check the oil level, Protective Mesh.
Semi-Annually:
Check cooling fan and coupling
Annually
: Check
Bearings/ Shaft Seals, More frequently if operated at ambient temperature
exceeding 20°C
Every 5000 operating hours:
Check the gear oil conditions, and if necessary, change the oils.
Inspection hole with G1" plug: Check the coupling and its insert, and fan through this hole regularly. (The