The motor must be connected according to the electrical codes through a fused switch in order to   protect the 

motor against electrical or mechanical overload conditions. The overload of the motor starter must be set at a level 

equal to the full load motor current listed on the motor nameplate. 

If the compressor is supplied with a motor starter, it is preset at the factory according to customer specifications. It is 

advisable to check that these settings are in line with the voltage at your location. If the voltage 

is different, please contact 

I.VA.CO.

 for motor and starter information.

C

orrect direction of rotation is marked by an arrow on the motor fan housing and is counterclockwise when

 

looking 

at the motor from the motor's fan side.

 

After electrical connections have been made, the rotation of the motor should be checked. If backward, 

reverse any two leads of the three at the power connection.  

1. 1.5

Pressure Connections 

    Use a pipe size that is at least the size of the compressor inlet connections. Smaller lines result in a reduced 

compressor capacity. 

Compressors operating in parallel on a common main line should have a manual or automatic operated   

shut-off valve or positive action check valve, installed in the suction line adjacent to the pump suction   

flange. Remove the plastic protective cap from the discharge port prior to connection of compressor to the system. 

    Should process gas contain dust or other foreign particles, a suitable in line (inlet) filter should be connected to 

the inlet port. Consult 

I.VA.CO:. for r

ecommendations.

Star Connection 

High Voltage 

L1 

L2 

L3 

W2 

U2 

V2 

U1 

V1 

W1 

The following thread sizes are standard on the compressors (NPT thread is available upon request) 

Inlet Size

 

Exhaust Size 

G 2" 

Model

   

ICP

 255 & 305

ICP

 405 & 515

G 3" 

G 2" 

    G 3" 

@ Inlet Silencer 

@Exhaust Connection Housing 

1.6    Oil Filling on Gear Box 

The pump is shipped without oil in gear box. After level installation and correct rotation has been established, 

fill the pump with recommended gear oil through the oil fill port. Oil level should be over 3/4 position on the 

oil sight glass as shown on the label.  

Содержание ICP 255

Страница 1: ...I VA CO srl Installation And Operating Manual ICP SERIES VACUUM PUMP MODELS 255 305 415 515 www ivaco it 2 2017 REV1 ...

Страница 2: ... 1 0 INSTALLATION 1 1 General description 1 2 Unpacking 1 3 Location 1 4 Power Requirements 1 5 Pressure Connections 1 6 Oil Filling on Gear box 2 0 SAFETY 2 1 General Notices 2 2 Warning Label and explanation 2 3 Location of Labels 3 0 OPERATION 3 1 Start up 3 2 Stopping the compressor 3 3 Ambient operating conditions This manual is written to cover following contact less operating claw type comp...

Страница 3: ...signs of damage incurred in transit Since all compressors are ordinarily shipped F O B from our factory or regional warehouse such damage is the normal responsibility of the carrier and should be reported to them The compressor is bolted to the skid with studs that are connected through the rubber feet of compressor Remove the nuts from the underside do the crate and remove the compressor Unscrew ...

Страница 4: ... is at least the size of the compressor inlet connections Smaller lines result in a reduced compressor capacity Compressors operating in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the suction line adjacent to the pump suction flange Remove the plastic protective cap from the discharge port prior to connection...

Страница 5: ...ped immediately I VA CO shall have no liability for any accident and failure arising from no compliance with instructions in this manual 2 2 Warning labels and its explanation Following warning labels are shown and attached on ICP series compressors 2 2 1 Read and Understand a manual Read and understand operator s manual before using this machine 2 2 2 Burn Hazard Hot surface Do not touch 2 2 3 Lo...

Страница 6: ...tion Do not run the compressor without regulating valve or safety valve Do not set the regulating valve or safety valve at over permissible pressure The compressor may be damaged severely The standard version is for use of dry air only and may not be used in hazardous areas Handling of humid air or gases containing aggressive chemicals is possible only with specially configures units Consult I VA ...

Страница 7: ...replaced when dirty Consult service agent for replacement element information Caution Depending on the mounting position of the filter be careful not to allow accumulated foreign material to fall in the pump suction inlet when removing the filter cartridge Horizontal filter installation is recommended to prevent this 4 3 Maintenance Chart Weekly Check inline inlet filter element More often if high...

Страница 8: ...tamination of the claws Remedy Clean the pumping chamber and rotary claws 5 4 2 Possible cause Coupling insert is worn Remedy replace coupling insert in motor pump coupling 5 4 3 Possible Cause Bearing noise Remedy replace bearings or call service agent for service or exchange program 5 5 Problem Compressor will not start 5 5 1 Possible Cause Supply voltage is not proper or is overloaded Motor sta...

Страница 9: ...13 18 13 18 22 26 18 26 36 50Hz 7 5 11 7 5 11 15 11 15 18 5 22 15 18 5 22 30 RPM 60 50Hz RPM Voltage Available V 60Hz 50Hz Oil Capa Gear box Ltr Inlet Outlet Conn BSP G W x H mm 60Hz 1001 1171 1171 1171 1183 1183 1274 1274 1340 1395 1289 1410 1410 50Hz 961 1171 973 1183 1183 1274 1274 1274 1340 1289 1289 1355 1410 Amb Operating Temp ºC Accessories 400 500 ICP 255 ICP 305 ICP 405 ICP 515 300 360 48...

Страница 10: ...A B 50Hz 7 5Kw 961mm 60Hz 9 2Kw 1 001mm 50Hz 11Kw 1 171mm 379mm 60Hz 15Kw 1 171mm 379mm 60Hz 15Hp 1 139mm 389mm 60Hz 20Hp 1 183mm 433mm 60Hz 25Hp 1 239mm 468mm 166 494 646 757 398 573 501 474 96 611 731 34 B A ...

Страница 11: ... B 50Hz 7 5Kw 973mm 50Hz 11Kw 973mm 379mm 50Hz 15Kw 973mm 379mm 60Hz 15Kw 973mm 379mm 60Hz 18 5Kw 973mm 379mm 60Hz 20Hp 1 195mm 433mm 60Hz 25Hp 1 251mm 468mm 34 B A 625 745 646 757 398 573 474 474 96 414 180 494 ...

Страница 12: ...ASS y DRAWING ICP 255 305 IEC ...

Страница 13: ...ASS y DRAWING ICP 255 305 NEMA ...

Страница 14: ... 5 24 Bearing cover 1 94 Shield Cover Side 1 643 Hex Socket Head Cap Screw M6 x 10 4 25 Key for Gear 2 95 Shield Cover Front 1 644 Hex Socket Head Cap Screw M6 x 15 12 26 Key for Coupling 1 96 Accoustic Mat for Shield Cover front and Side 1 650 Hex Socket Head Cap Screw M6 x 65 4 27 Sleeve 2 97 Foot Rubber 7 656 Hex Socket Head Cap Screw M12 x 25 2 28 Power Lock ICP 305 2 4 100 Coupling Pump Side ...

Страница 15: ...mm 50Hz 15Kw 1 274mm 60Hz 15Kw 1 274mm 50Hz 18 5Kw 1 274mm 60Hz 18 5Kw 1 274mm 50Hz 22Kw 1 340mm 346mm 60Hz 22Kw 1 340mm 346mm 60Hz 30Kw 1 395mm 514mm 60Hz 20Hp 1 286mm 60Hz 25Hp 1 287mm 438mm 60Hz 30Hp 1 381mm 510mm 60Hz 40Hp 1 391mm 494mm ...

Страница 16: ... B 50Hz 15Kw 1 289mm 50Hz 18 5Kw 1 289mm 60Hz 18 5Kw 1 289mm 50Hz 22Kw 1 355mm 346mm 50Hz 30Kw 1 410mm 514mm 60Hz 30Kw 1 410mm 514mm 60Hz 37Kw 1 410mm 514mm 60Hz 25Hp 1 302mm 60Hz 40Hp 1 406mm 494mm 60Hz 50Hp 1 444mm 532mm ...

Страница 17: ...ASS y DRAWING ICP 405 515 IEC ...

Страница 18: ...ASS y DRAWING ICP 405 515 NEMA ...

Страница 19: ... Socket Head Cap Screw M5 5 25 Key for Gear 2 94 Shield Cover Side 1 643 Hex Socket Head Cap Screw M5 4 26 Key for Coupling 1 95 Shield Cover Front 1 644 Hex Socket Head Cap Screw M6 16 27 Sleeve 2 96 Accoustic Mat for Shield Cover front and Side 1 651 Hex Socket Head Cap Screw M16 4 28 Power Lock ICP 515 2 4 97 Foot Rubber 9 653 Washer Spring Lock 16mm 4 30 Flinger 2 100 Coupling Pump Side 1 656 ...

Страница 20: ...I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy 39 039 9281084 info ivaco it www ivaco it ...

Отзывы: