5. 6 Problem
Compressor is running too hot abnormally.
5.6.1 Possible Cause
Not enough air ventilation to compressor.
Remedy
: Make certain a sufficient amount of fresh air is supplied to the compressor.
5.7 Problem
Compressor will not operate (seized up).
5.7.1 Possible cause
Rotary Claws, Bearings or Gears stuck on.
Remedy
: Call service agent for service or exchange program
6.0 TECHNICAL DATA
Model
ICP 100
M3/ Hour
60Hz
120
50Hz
100
Press., conti., Bar
60Hz
~
1.4
2.2
50Hz
0.8
1.4
2.2
Kw
60Hz
~
4.8
6.5
50Hz
3
4
5.5
RPM - 60/50Hz
RPM
3450/2850
Voltage, Available
V
208~230/460V,
220/380V. 230/400V,
400/690V
dB(A), Ave
60Hz
83
50Hz
79
Oil Capacity (Gear
box)
Ltr
0.75
Inlet/Outlet
Connections
BSP(G)
1-1/2"
W x H (mm)
488 x 618/673^(5.5kw+)
L* x W x H (mm)
60Hz
778
778
50Hz
717
742
778
Amb. Operating
Temp(ºC)
5ºC ~40ºC
Approx. *Weight (Kg).
60Hz
~
135
150
50Hz
108
120
140
Accessories
Pressure Regulator, Safety Valve, Inlet Silencer, and Inlet Filter
* Varies to motor mfg /NPT threads available
upon request