4.0    MAINTENANCE 

    ICP-Series compressors require very little maintenance. To ensure optimum performance, the 

following maintenance steps should be followed: 

4.1    Compressor Lube Oil 

4.1.1    Oil Level 

    Check the oil level on monthly basis. Under normal circumstances it should not be necessary to add oil 

between oil changes. A significant drop in oil level means there is an oil leak. Please check the o-rings, 
drain plug or oil sight glass. 

Check the oil level only when the compressor is shut off. Replenish oil if it drops below bottom position of 
the sight glass. 

Caution: Do not add oil while the compressor is running, since hot oil can escape from the oil fill 

port. 

4.1.2    Oil Type and Quantity 

    See section 1.5 - Oil Filling - for details on oil type and quantity 

4.1.3    Oil Change 

Under normal ambient conditions with proper Gear Oil, it is recommended to change the oil every 10,000 

operating hours. It is necessary to make the first oil change between 500 ~1000 operating hours. 

Caution: If different brand oil is being filled, the old oil must be drained completely from the gear box. 

4.2    Inline (Inlet) Filter 

    Check inline (inlet) filter on a weekly basis. The filter cartridge should be cleaned or replaced when 

dirty. Consult service agent for replacement element information. 

Caution: Depending on the mounting position of the filter, be careful not to allow accumulated   

foreign material to fall in the pump suction inlet when removing the filter cartridge. Horizontal filter 

installation is recommended to prevent this. 

3.3  Operating Conditions 

The ambient and suction air temperature must be between 5 and 40 

°

C deg. The standard versions may 

not be used in hazardous areas. Also it is recommended for operating personnel who is working near 

compressor to wear ear protectors. 

Caution: Any non compliance may lead to severe injury to persons and damage to the pump.

The pressure can be adjusted by turning knob of pressure regulating valve as marked on the top of valve. 

The regulating valve or safety valve is set at permissible operating pressure and will be opened to 

discharge the pressure if the compressor runs over the setting pressure for a safety operation. 

Caution: Do not run the compressor without regulating valve or safety valve. Do not set the regulating 

valve or safety valve at over permissible pressure. The compressor may be damaged severely. 

4.3    Maintenance Chart 

Weekly:   

Check inline inlet filter element / Mesh. More often if high particulates in inlet stream 

Monthly:   

Check the oil level, Protective Mesh. 

Semi-Annually:   

Check cooling fans and coupling 

Annually:   

Check

 

Bearings / Shaft Seals, More frequently if operated at ambient temperature 

exceeding 20°C

   

Every    5,000 operating hours:

 Check the gear oil conditions, and if necessary, change the oils. 

Содержание ICP 100

Страница 1: ...allation and Operating Manual ICP SERIES VACUUM PUMP MODEL 100 2 2017 REV1 I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy Tel 39 039 9281084 info ivaco it www ivaco it ...

Страница 2: ...f Labels 3 0 OPERATION 3 1 Start up 3 2 Stopping the compressor 3 3 Ambient operating conditions 4 0 MAINTENANCE 4 1 Compressor Lube Oil level type quantity change 4 2 Inlet filter 4 3 Maintenance chart 5 0 PROBLEM SOLVING 6 0 TECHNICAL DATA 7 0 TYPICAL ICP SERIES ASSEMBLY DRAWING AND PARTS LIST INSTALLATION AND OPERATING MANUAL This manual is written to cover following contact less operating claw...

Страница 3: ...pling The ICP Series compressors are identical in internal construction to ICV vacuum pump but are outfitted with different inlet and outlet accessories to allow for operation as a compressor 1 2 Unpacking Inspect the box and compressor carefully for any signs of damage incurred in transit 1 3 Location Install the compressor in a horizontal position on a level surface so that it can be evenly supp...

Страница 4: ...ng pipe lines result in a reduced compressor capacity Compressors operating in parallel on a common main line should have a manual or automatic operated shut off valve or positive action check valve installed in the pressure line Remove the plastic protective cap from the exhaust port prior to connection of compressor to the system Should process gas contain dust or other foreign particles a suita...

Страница 5: ...2 Warning labels and its explanation Following warning labels are shown and attached on ICP series compressor 2 2 1 Read and Understand a manual Read and understand operator s manual before using this machine 2 2 2 Burn Hazard Hot surface Do not touch 2 2 3 Loud noise Hazard Loud noise hazard Ear protection must be worn 2 2 4 Hazardous Voltage Disconnect power before opening Contact causes severe ...

Страница 6: ...Depending on the mounting position of the filter be careful not to allow accumulated foreign material to fall in the pump suction inlet when removing the filter cartridge Horizontal filter installation is recommended to prevent this 3 3 Operating Conditions The ambient and suction air temperature must be between 5 and 40 C deg The standard versions may not be used in hazardous areas Also it is rec...

Страница 7: ...nation of the claws or chamber Remedy Clean the pumping chamber and the claws 5 4 2 Possible cause Coupling insert is worn Remedy replace coupling insert in motor compressor coupling 5 4 3 Possible Cause Bearing noise Remedy replace bearings or call service agent for service or exchange program 5 4 4 Possible Cause Pressure regulator or safety valve noise Remedy replace Pressure regulator or Safet...

Страница 8: ...L DATA Model ICP 100 M3 Hour 60Hz 120 50Hz 100 Press conti Bar 60Hz 1 4 2 2 50Hz 0 8 1 4 2 2 Kw 60Hz 4 8 6 5 50Hz 3 4 5 5 RPM 60 50Hz RPM 3450 2850 Voltage Available V 208 230 460V 220 380V 230 400V 400 690V dB A Ave 60Hz 83 50Hz 79 Oil Capacity Gear box Ltr 0 75 Inlet Outlet Connections BSP G 1 1 2 W x H mm 488 x 618 673 5 5kw L x W x H mm 60Hz 778 778 50Hz 717 742 778 Amb Operating Temp ºC 5ºC 4...

Страница 9: ...ASS y DRAWING ICP100 IF IEC ICP ICP ICP ICP ICP ICP ICP ...

Страница 10: ...ASS y DRAWING ICP 100 IF NEMA ICP ICP ICP ICP ...

Страница 11: ...95 Shield Cover Front with mat 1 213 Hexagon Bolt M12 x 25 4 25 Key for Gear 2 96 Accoustic Mat for Shield Cover front and Side 1 214 Hexagon Bolt NEMA only 4 26 Key for Coupling 1 97 Foot Rubber 30x20xM8 50x30xM10 4 215 Set Screw M8 x 10 2 28 Power Lock 2 98 Cover Plastic Foot Mount ICP high 4 6 216 Set Screw M8 x 10 2 29 Washer Spring Lock 6mm 2 99 Grill for Fan 2 217 Round Head Bolt M5 x 12 5 3...

Страница 12: ...I VA CO Italian Vacuum Compressors Via delle Brigole 33 23877 Paderno d Adda LC Italy 39 039 9281084 info ivaco it www ivaco it ...

Отзывы: