
I-Tork PDS Pneumatic Actuator
Installation and operating manual (PDS-M0108/1010)
I-TORK PDS PNEUMATIC ACTUATOR
13
13
13
13
Disassembling of Spring Pack:
For safe disassembling of the spring packs, the following procedure must be carried
out.
1.
Disconnect all air and electrical supplies.
2.
Springs must not be in the compress position (that is, the springs must be at
fully extended position).
3.
Loosen the bolts (26) of the end cover separate Spring Pack from the body.
Spring Packs
Pretension Bolt(33)/Spring Washer(32)/Plain Washer(31)/Spring Retainer(30)
Spring(29)/O-Ring(22)/Spring Cover(28)/Bolt(26)
From PS 40 to PS100 (Single Spring per pack)
There are 2 Spring Options:
One is for 4.2 bar pressure;
The other is for 5.5 bar pressure.
From PS 125 to PS200 (Double Springs per pack)
There are 2 Spring Options:
One is for 4.2 bar pressure.
The other is for 5.5 bar pressure.
<Remark>
When placing order PS Single Acting type Pneumatic Actuator,
please specify the Spring Option (4.2 bar or 5.5 bar).