background image

i

SET

START

RESET

AT

-therm

i

Px-728

T

T

S

1

2

PV

SV

i

-therm

Px-428

AT

START

RESET

SET

T

S

1

2

2

MECHANICAL  INSTALLATION

The label on the controller identifies the serial number, wiring connections and batch number.

 

CAUTION: 

To prevent the risk of electrical shock, switch off the power before making/removing any connection or removing 

the controller from  its enclosure.

ELECTRICAL INSTALLATION

The electrical connection diagram is shown on the controller enclosure as below.

Px-428

Px- 728

OVER ALL DIMENSIONS & PANEL CUT OUT (IN MM)

INSTALLATION GUIDELINES :

3.  Push  the  controller  through  panel  cut-out  and  secure  the   
controller in its place by tightening the side clamp.

2.   Remove clamp from controller 

1.   Prepare the cut-out with proper dimension as shown in figure.      

MODEL:Px428/728/928  

A

E

F

PANEL

CUTOUT

FRONT PANEL LAYOUT

FRONT PANEL LAYOUT DESCRIPTION :

Glows when OP1 is ON & flashes when delay time (dly1) is in operation (if selected mode is ON-OFF)

Glows when OP2 is ON & flashes when alarm condition persists even after acknowledged OR delay time (dly2) is in operation & 
selected mode is ON-OFF.

Glows when Soak mode is selected & flashes when soak timer is in operation.

(1) For SP programming. (2) To access Control mode. (3) To access Configuration mode along with UP key. (4) To scroll the 
parameter & to store its value.

(1) To increase/alter parameter value in program mode. (2) To enter in configuration mode (with SET key). (3) To acknowledge Alarm. 
(4) To enter in tune mode (with DOWN key). 

(1) To decrease/alter parameter value in program mode. (2) To enter in tune mode (with UP key). 

It will display (1) Measured value of selected input or Error messages in run mode. (2) Parameters value in program mode.

It will display (1) SP (Main set point) / SP2 (Auxiliary/Alarm) set value / Set Soak time value/ balance or elapsed soak time in run 
mode. (2) Parameter code in program mode. 

1

2

3

4

5

6

7

Sr. 

NAME

FUNCTION

(1) To increase/alter parameter value in program mode with Up / Dn key.
(2) Press for 3sec in programming, this will help to go back to previous parameter.

OP1 LED

OP2 LED

SOAK LED

 UPPER
DISPLAY
 LOWER
DISPLAY

SET
KEY

SHIFT
  KEY

 UP
KEY

DOWN
  KEY

OIM Px-X28 V2.0 Page 1 of 9

Px- 728

50

3

70

45

45

45

TABLE : 1

Model

Dim

A

B

C

D

F

G

E

Px- 428

Model no.

Weight (gms.)

Px-428 Px-728

50

72

72

3

60

68

68

68

130

200

Px-428

Px-728

4

5

7

1

2

3

6

4

5

7

1

2

3

6

OP2

NO

NC

CM

1

6

10

3

2

4

5

8

NO

NC

CM

OP1-RLY

9

7

OP1-SSR

12

13

11

15

14

16

Digital I/P

R

W

W

i

OP2-RLY

NO

NC

CM

OP1-RLY

NO

NC

CM

w

w

R

1

2

3

4

5

6

7

14

13

12

11

10

9

8

15

18

20

19

16

17

Digital I/P

OP2-SSR   OP1-SSR

i

PV

SV

Содержание Px-428

Страница 1: ...ads v Circuit breaker and appropriate fuses must be used for v The controller must be wired as per wiring diagram it to high voltage surges of extended duration high current power cables Where it is i...

Страница 2: ...1 For SP programming 2 To access Control mode 3 To access Configuration mode along with UP key 4 To scroll the parameter to store its value 1 To increase alter parameter value in program mode 2 To ent...

Страница 3: ...ed as soak timer Controller starts the execution of soak time as per the mode selected Soak timer can be programmed using four different time base in Config List 1 Either absolute auxiliary control or...

Страница 4: ...Output1 is configured for Heat Cool SP set point will be consider as SP Gap1 for heating This parameter will be prompted only if selected control mode for output2 is Auxiliary control or an Alarm The...

Страница 5: ...ut is ON PV decreases when output is ON User can select cooling logic in which OP1 will remain ON till PV SP This parameter will be prompted only if selected input is RTD or RTD 1 and is used for BOD...

Страница 6: ...vated By pressing DOWN key Lower display will Toggle between SP1 value SP2 value Alarm SP Value AL SP Timer value SOAK By this parameter Lower display will only show the SP1 value By this parameter Lo...

Страница 7: ...ompletion of current soak time cycle 1 At every Power ON 3 Power failure during soak time is in progress In this Mode Timer will start only after pressing START key for 3 sec PV SV for any of the foll...

Страница 8: ...will Disable Alarm O P at power ON If this parameter is set as NO Alarm condition persists it will Enable Alarm O P at power up Once the Alarm is activated User has following three options to de activ...

Страница 9: ...remains OFF till actual temperature drops down in Heat Logic or raises in Cool Logic equal to hysterisis set by user As shown in Fig 3 1 3 2 If the control performance by using auto tuning is still u...

Страница 10: ......

Страница 11: ......

Страница 12: ...remains OFF till actual temperature drops down in Heat Logic or raises in Cool Logic equal to hysterisis set by user As shown in Fig 3 1 3 2 2 Substantial change in SP from previous auto tuning value...

Отзывы: