background image

i

6

OIM BL-886 V1.2 Page 6 of 6

Default

Description

Display

Parameter

E-mail : [email protected] 
Website : www.itherm.co.in  

338, New Sonal Link Service Industrial Premises Co-op Society Ltd,

Tel: 022-66939916/17/18; 

Building No.2, Link Road, Malad (W), Mumbai - 400064. 

Mfgd  by:  Innovative  Instruments  &  Controls  LLP

i

Reso-
lution

0.

1000

Scale

Factor

0.00001 

to

999999

1000.

Set DP

Point

This option doesn't appear if the dot position for scale is at 6th position(LSB 
position). User can set screen resolution for RUN Mode. & for Set Count.

000000

to

0.00000

User  can  set  desired  Scale  Factor  value.  'SCAL'  will  be  displayed  on  lower 
display  &  last  stored/default  value  of  Scale  will  be  displayed  on  upper 
display.  User  can  change  this  value  by  using  Up/Down/Shift  key.  Press  'set' 
key to store the desired value & move to next parameter.

000000

to

0.00000

User  can  set  position  of  decimal  point  for  scale  factor. The  last  set  value  of 
scale  will  appear  on  the  upper  display  &  the  lower  display  will  toggle  b/w 
“SELt” & “DP”. Position of decimal point can be shifted from LSB to MSB by 
using the shift key.

Leading

Zero

Disable

User

Lock

15

Enable:-

 If selected Leading Zeros will display in Run mode.

Lead-0:- 

This  parameter  allows  the  user  to  Enable  or  Disable  Leading  Zeros  in  Run 

mode. 

Disable:-

 If selected Leading Zeros will not comes in Run mode.

Default User Lock Code is “15" to access Control & Configuration List.
User has a choice to set its own User Lock Code between 1 to 9999, this is to prevent 
unauthorized access of Configuration List.

Отзывы: