Configuration Mode
(1) To enter in this mode, Press and hold SET & UP key simultaneously for 3 sec.
(2) Press UP or DOWN key to scroll between parameter options.
(3) Press SET key to store the current parameter & move on to the next parameter.
Input
Freq.
Medium
Lock
Code
0
Default
Display
Parameter
Type
Batch
OP2F
Batch
Mode
Mode
1
Front
Reset
Enable
10.00
mm
Diameter
Very High Frequency:-
If selected; Count Input Frequency up to 2.5KHz.
High Frequency:-
If selected; Count Input Frequency up to 1KHz.
Medium Frequency:-
If selected; Count Input Frequency up to 100Hz.
Low Frequency:-
If selected; Count Input Frequency up to 30Hz.
Very Low Frequency:-
If selected; Count Input Frequency up to 3Hz.
User can select an option from Very Low/Low/Med/High/Very High according to the
frequency of count pulse at the input terminal. This feature is useful in avoiding noise
signal.
Set this parameter to 15 (Default LOCK CODE) to access Configuration List.
User has a choice to set different Lock Code in the range 1 ~ 9999 via USER LOCK
CODE in Configuration List.
Description
User can select an option between Batch Type, Length Type & Preset Type.
Batch Type :
If Selected Instrument will Work as Batch Counter.
Length Type :
If Selected Instrument will Work as Length Counter.
Preset Type :
If Selected Instrument will Work as Preset Counter.
Batch:-
If selected, Output2 used as Batch Output. When Batch Count Equal to Set
Batch Output2 will Turn on. Output 2 will turn off by pressing Down/Reset Key for 3Sec.
in View Mode.
Set Count 2:-
If selected, Output2 used as independent Set Point. When Running Count
Equal to Set Count 2 Output2 will Turn on. Output 2 will turn off, depending on Time
Parameter or by pressing Down/Reset Key.
Note:- This parameter will appears only if Mode as Mode 1 Selected.
Auxiliary:-
If selected, Output2 have same function as Output 1.
Off:-
If selected, Output2 is not used & cab be kept reserve for future use.
This parameter will occurs only if Batch type is selected.
Mode - 1:
In this mode Relay1 & Buzzer will Turn Off simultaneously depending on “Time
parameter” value in Set mode.
Mode - 2:
In this mode Relay1 & Buzzer will Turn Off depending on “Set Count - Off”
Value in Set mode.
ENABLE:
If selected; user can reset the Running Count & Total Count by pressing
Down/Reset key located at front panel.
DISABLE:
If selected; user can not reset the counter by pressing down key located at
front panel. Only remote reset at back terminal is allowed. This feature is useful to avoid
unauthorized attempt to reset the counter during run mode.
User can set desired Diameter value. 'dIA' will be displayed on lower display
& last stored/default value of ‘Dia Meter' will be displayed on upper display.
User can change this value by using Up/Down/Shift key. Press 'set' key to
store the desired value & move to next parameter.
0.01 to
9999.99
mm