Step 3

 Setting the Year

The meter will say "Set year" if the talking 

function is on. Press 

 or 

 button until correct 

year appears. Press and hold 

 or 

 to scroll 

faster. After setting the year, press the S button 

to confirm your selection and set the month.

Step 4

 Setting the Month

A number indicating the month will blink on 

the bottom left corner of the screen. If the 

talking function is on, the meter will say "Set 

month." Press 

 or 

 button until the correct 

month appears. Press the S button to confirm 

your selection and set the date.

Step 5

 Setting the Date

The meter will say "Set date" when the talking 

function is on. Press 

 or 

 button until 

blinking number shows the correct date. Press 

the S button to confirm the date and set the 

time.

Step 6

 Setting the Time Format

The meter can be set in the AM/PM (12-hour) or 

the 24-hour clock format. If the talking function 

is on, the meter will say "Set time 12-hour / 24 

hour." Press 

 or 

 button to select a format. 

The AM/PM is not displayed in the 24-hour 

format. After selecting the format, press the S 

button to set the hour.

Step 7

 Setting the Hour

If the talking function is on, the meter will say 

"Set hour." Press 

 or 

 button until the correct 

hour appears. Press the S button to confirm the 

hour and set the minute.

Step 8

 Setting the Minute

If the talking function is on, the meter will say "Set 

minute." Press 

 or 

 button until the correct 

minute appears. After setting the minute, press 

the S button to set the sound.

Содержание CareSens N Voice

Страница 1: ...r s lo Sistema de Monitoreo de Glucosa en Sangre Manual del Usuario Funci n de voz L No Codificaci n Segundos For single user home use only Blood Glucose Monitoring System User s Manual No Coding Talk...

Страница 2: ...professional or emergency medical response Bien venido al Sistema de Monitoreo de Glucosa CareSens N Voice Gracias por elegir el Sistema de Monitoreo de Glucosa en Sangre CareSens N Voice El sistema l...

Страница 3: ...d Glucose Testing Using the Lancing Device 23 Preparing the Lancing Device 24 Preparing the Meter and Test Strip 25 Flagging Post meal Test Results 26 Applying the Blood Sample 27 Discarding Used Lanc...

Страница 4: ...rips to check that the meter and the test strips are working together properly and that the test is performing correctly The CareSens N Voice Blood Glucose Monitoring System is intended for in vitro o...

Страница 5: ...N Voice Blood Glucose Meter User s Manual Quick Reference Guide Batteries 2 CareSens N Voice System may include the following items CareSens N Single Blood Glucose Test Strips 10 Lancing Device Lancet...

Страница 6: ...ever you may need to reset your meter settings See page 13 CareSens N Single Blood Glucose Test Strip The CareSens N Voice Blood Glucose Monitoring System measures blood glucose quickly and accurately...

Страница 7: ...er test strips in any way For detailed storage and usage information refer to the CareSens N Single Test Strip package insert Keep the meter and testing supplies away from young children Note You can...

Страница 8: ...date the meter settings such as time and date before using your meter or when you change the meter batteries Press and hold the S button for 3 seconds to enter the SET mode While you are setting the m...

Страница 9: ...ion is on Press or button until blinking number shows the correct date Press the S button to confirm the date and set the time Step 6 Setting the Time Format The meter can be set in the AM PM 12 hour...

Страница 10: ...20 mg dL Step 10 Turning on the Hypoglycemia Indicator When you enter the hypoglycemia indicator setting mode the symbol and HYPo will blink If the talking function is on the meter will say Set hypogl...

Страница 11: ...using the control solution shake the bottle discard the first 1 or 2 drops and wipe the tip clean Close the control solution bottle tightly and store at a temperature of 46 86 F 8 30 C You should do...

Страница 12: ...solution test result by pressing and holding the button for 3 seconds until the ctl appears on the display When the ctl is displayed the result is stored in the meter s memory but is not included in t...

Страница 13: ...ned plus three 3 months When the control solution is contaminated Situations Actions Repeat the control solution test by referring to the Notes on page 18 Discard the used control solution and repeat...

Страница 14: ...h of penetration by rotating the top portion of the adjustable tip until the setting number matches the arrow Step 5 Cock the lancing device by holding the body in one hand and pulling on the sleeve w...

Страница 15: ...ng the blood sample or when the test result is displayed just after testing Once the test result is saved with the post meal flag it cannot be deleted Step 9 After the symbol appears on the screen app...

Страница 16: ...of the symbol appearing on the screen If the meter turns off press S button or button and apply the blood sample after the symbol appears on the screen Step 1 Unscrew the lancing device tip Step 2 Pla...

Страница 17: ...device changes color Then press the release button while continuing to apply pressure Keep holding the lancing device against your skin until sufficient at least 0 5 L blood is drawn Carefully lift t...

Страница 18: ...e to contact with hair or with lines on your palm do not use that sample Try puncturing again in a smoother area Note If messages for hyperglycemia or hypoglycemia are displayed even if you do not hav...

Страница 19: ...isplayed when the data cable connects the meter with computer For more information contact Customer Service at 1 800 429 5001 Meter Memory Step 1 Press the S or button to turn on the meter If the talk...

Страница 20: ...previously To turn off the meter press the S button button button Post meal average 1 7 14 30 90 days button button Pre meal average 1 7 14 30 90 days Step 2 Use the button to scroll through the store...

Страница 21: ...ut symbol being displayed Setting the Alarm Function Setting the Post meal Alarm PP2 alarm Four types of alarms can be set in the CareSens N Voice Meter one post meal alarm PP2 alarm and three time se...

Страница 22: ...d lancing device should be disinfected prior to use by the second person Pre cleaning procedure is needed to clean dirt as well as blood and other body fluids on the exterior of the meter and lancing...

Страница 23: ...the disinfectant product please contact the manufacturer or visit their website as listed above Name Manufacturer EPAregistration number Active ingredients Clorox Germicidal Wipes Clorox Professional...

Страница 24: ...nfectants because other chemicals have not been validated and may damage the meter Do Not get fluids inside the meter through the test strip port data transmission port or battery compartment Never im...

Страница 25: ...n or technical assistance by calling our Customer Service Center 1 800 429 5001 9 am 9 pm EST Monday Saturday Message What is said Error 1 Used test strip Error 2 The sample has been applied before th...

Страница 26: ...Customer Service 1 800 429 5001 9 am 9 pm EST Monday Saturday Message What is said What it means What to do Error 6 Error 7 Error 8 Error 9 Meter failure There is a problem with the meter Do not use t...

Страница 27: ...pm EST Monday Saturday Within 5 Within 10 Within 15 Within 20 54 93 58 82 93 88 93 93 100 93 93 100 Within 5mg dL 14 17 82 17 17 100 17 17 100 Within 10mg dL Within 15mg dL Performance Characteristics...

Страница 28: ...omparison of results using various AST sites with the results of YSI measurements Alternative site test results for glucose concentration 75 mg dL Within 5mg dL Within 10mg dL Within 15mg dL Fingertip...

Страница 29: ...r handling tampering use or service of the meter Any claim must be made within the warranty period The i SENS Inc will at its discretion repair or replace a defective meter or meter part that is cover...

Отзывы: